Optimization of Fenton and electro-Fenton oxidation of biologically treated coking wastewater using response surface methodology
Optimization of Fenton and electro-Fenton oxidation of biologically treated coking wastewater using response surface methodology
复制标题
DOI:
10.1016/j.seppur.2011.08.023
复制
发表时间:
2011-10
影响因子:
8.6
通讯作者:
Xiaobiao Zhu;Jinping Tian;Rui Liu;Lu-jun Chen
中科院分区:
文献类型:
--
作者:
Xiaobiao Zhu;Jinping Tian;Rui Liu;Lu-jun Chen
In this study, Fenton and electro-Fenton were employed to treat biologically stabilized coking wastewater, i.e. the effluent of a biological coking wastewater treatment. The Box–Behnken experimental design (BBD) and response surface methodology (RSM) were used to design and optimize the performance of both processes. The regression quadratic model describing the TOC removal efficiency of Fenton and electro-Fenton process was developed and validated by the analysis of variances (ANOVA), respectively. The significance levels of linear and interaction effects of the reaction parameters on processes efficiencies were obtained. The optimum parameters were determined as pH 4, 1.2h reaction time, 40mM of Fe2+and H2O2for Fenton reaction; and pH 4, 1.8h reaction time, 0.6mM of Fe2+and 3.7mA/cm2of current density for electro-Fenton. The corresponding TOC removal efficiencies were about 75% and 55% for Fenton and electro-Fenton, respectively. Both Fenton and electro-Fenton are effective in advanced treatment for coking wastewater, and the response surface methodology is suitable for the design and optimization of the processes.