High-speed microfluidic differential manometer for cellular-scale hydrodynamics
High-speed microfluidic differential manometer for cellular-scale hydrodynamics
复制标题
DOI:
10.1073/pnas.0507171102
复制
发表时间:
2006-01-17
影响因子:
11.1
通讯作者:
Stone, HA
中科院分区:
文献类型:
--
作者:
Abkarian, M;Faivre, M;Stone, HA
We propose a broadly applicable high-speed microfluiclic approach for measuring dynamical pressure-drop variations along a micrometer-sized channel and illustrate the potential of the technique by presenting measurements of the additional pressure drop produced at the scale of individual flowing cells. The influence of drug-modified mechanical properties of the cell membrane is shown. Finally, single hemolysis events during flow are recorded simultaneously with the critical pressure drop for the rupture of the membrane. This scale-independent measurement approach can be applied to any dynamical process or event that changes the hydrodynamic resistance of micro- or nanochannels.