Intracranial Aneurysm Embolization Using Interlocking Detachable Coils
Intracranial Aneurysm Embolization Using Interlocking Detachable Coils
复制标题
使用互锁可拆卸弹簧圈进行颅内动脉瘤栓塞
DOI:
--
复制
发表时间:
1997
影响因子:
1.7
通讯作者:
Shinji Nagahiro
中科院分区:
文献类型:
--
作者:
Koichi Satoh;Shunji Matsubara;H. Hondoh;Shinji Nagahiro
The relationship between volume embolization ratio and coil compaction on the intracranial aneurysm occluded using interlocking detachable coils (IDCs) was determined. From February 1994 to October 1996, 7 intracranial aneurysms were embolized using IDCs. Aneurysm capacity (volume) was calculated assuming that aneurysms are ellipsoid of the diameter in 3 planes. Coil volume was calculated assuming that IDCs are cylinders of primary coil. Coil compaction was observed in aneurysms embolized at a volume embolization ratio under 25%. There was no coil compaction in aneurysms embolized at a volume embolization ratio of over 25%. Measurement of the volume embolization ratio is useful to predict coil compaction. Intracranial aneurysms should be embolized at a volume embolization ratio of 25–33%.
DOI:
--
发表时间:
1994
期刊:
AJNR. American journal of neuroradiology
影响因子:
--
作者:
FernandezZubillaga,A;Guglielmi,G;Viñuela,F;Duckwiler,GR
通讯作者: