Indirect “one-side” cooling method of a magnetic-alloy–loaded rf cavity
Indirect “one-side” cooling method of a magnetic-alloy–loaded rf cavity
复制标题
DOI:
10.1103/physrevstab.7.122002
复制
发表时间:
2004-12
影响因子:
--
通讯作者:
T. Misu;A. Sugiura;S. Hojo;N. Miyahara;M. Kanazawa;Y. Iwata;T. Murakami;S. Yamada
中科院分区:
文献类型:
--
作者:
T. Misu;A. Sugiura;S. Hojo;N. Miyahara;M. Kanazawa;Y. Iwata;T. Murakami;S. Yamada
For magnetic alloy (MA) loaded rf accelerating cavity, we have developed an indirect cooling system, which is effective for retaining its shunt impedance by cooling only one side of the MA cores. Because of its low-high-permeability property, MA cores are suitable for constructing untuned broadband accelerating systems. Since these same cores are made of wound thin tape, the key to establishing an untuned broadband cavity with effective indirect cooling method is to suppress the reduction of core impedance when attaching metallic cooling plates to the core and keeping a good thermal contact between them. We have employed indium bonding to thermally connect both cores and cooling plates. Both cooling and endurance tests have demonstrated its successful results.