The Utility of Serum D-Dimer for the Diagnosis of Periprosthetic Joint Infection in Revision Total Hip and Knee Arthroplasty

The Utility of Serum D-Dimer for the Diagnosis of Periprosthetic Joint Infection in Revision Total Hip and Knee Arthroplasty
复制标题

DOI:
10.1016/j.arth.2020.01.034
复制
发表时间:
2020-06-01
影响因子:
3.5
通讯作者:
Higuera, Carlos A.
Higuera, Carlos A.
中科院分区:
医学2区
文献类型:
--
作者:
Pannu, Tejbir S.;Villa, Jesus M.;Higuera, Carlos A.

文献摘要

被引文献

相似文献

背景资料:在全髋关节(THA)和膝关节(TKA)翻修术中,使用血清D-二聚体诊断假体周围关节感染的证据很少且存在矛盾。因此,本研究的目的是测试血清D-二聚体对2013年国际共识会议(ICM)criteria.Methods的准确性:一项回顾性研究进行了一系列的172个修订THA/TICS手术进行了3个研究员培训的外科医生在一个单一的机构(2017年8月至2019年5月),并在他们的术前检查D-二聚体。在该队列中,111例(42例THA/69例TKA)病例完成了2013 ICM标准测试,并被纳入最终分析。根据2013 ICM标准(“金标准”)对脓毒症和无菌性翻修进行分类,并使用既定阈值(850 ng/mL)与血清D-二聚体进行比较。确定灵敏度、特异性、似然比和阳性/阴性预测值。独立的t检验,Fisher精确检验,卡方检验,和接收器操作特征曲线analysed.Results:有没有统计学意义上的基线人口统计学之间的败血症和无菌病例每2013年ICM标准的差异。与ICM标准相比,D-二聚体诊断假体周围关节感染的敏感性(95.9%)和阴性预测值(90.9%)较高,但特异性(32.3%)和阳性预测值(52.8%)较低,总体准确性较差(61%)。阳性似然比为1.42,阴性似然比为0.13。曲线下面积(AUC)为0.742。结论:在翻修THA和TKA的情况下,使用所描述的阈值区分感染性和无菌性病例的准确性较差。(C)2020爱思唯尔公司All rights reserved.
Background: There is scarce and contradicting evidence supporting the use of serum D-dimer for the diagnosis of periprosthetic joint infection in revision total hip (THA) and knee (TKA) arthroplasty. Therefore, the purpose of this study is to test the accuracy of serum D-dimer against the 2013 International Consensus Meeting (ICM) criteria.Methods: A retrospective review was performed on a consecutive series of 172 revision THA/TICS surgeries performed by 3 fellowship-trained surgeons at a single institution (August 2017 to May 2019) and that had D-dimer performed during their preoperative workup. Of this cohort, 111 (42 THAs/69 TKAs) cases had complete 2013 ICM criteria tests and were included in the final analysis. Septic and aseptic revisions were categorized per 2013 ICM criteria ("gold standard") and compared against serum D-dimer using an established threshold (850 ng/mL). Sensitivity, specificity, likelihood ratios, and positive/negative predictive values were determined. Independent t-tests, Fisher's exact tests, chi-squared tests, and receiver operating characteristic curve analysis were performed.Results: There was no statistically significant difference in baseline demographics between septic and aseptic cases per 2013 ICM criteria. When compared to ICM criteria, D-dimer demonstrated high sensitivity (95.9%) and negative predictive value (90.9%) but low specificity (32.3%), positive predictive value (52.8%), and overall, poor accuracy (61%) to diagnose periprosthetic joint infection. Positive likelihood ratio was 1.42 while negative likelihood ratio was 0.13. The area under the curve (AUC) was 0.742.Conclusion: Serum D-dimer has poor accuracy to discriminate between septic and aseptic cases using a described threshold in the setting of revision THA and TKA. (C) 2020 Elsevier Inc. All rights reserved.