中文摘要
大鼠的胆管很薄,注射泊洛沙姆一直很困难。为此,我们尝试使用泊洛沙姆进行门静脉吻合术。将泊洛沙姆注入大鼠门静脉,确保腔内可见。但由于缺乏力量指导,吻合口一直难以稳定。无法获得因吻合口出血和血栓栓子而存活的患者。当它注入小直径的管腔时,泊洛沙姆强度不足,被认为不足以作为确保管腔的指南。
英文摘要
Bile duct of rats very thin, injection of poloxamer has been difficult. For this reason, we tried to portal vein anastomosis using a poloxamer. Injected poloxamer into the portal vein of rats, ensure the lumen was possible. However, there is a lack of strength as a guide, anastomosis stable has been difficult. Survivors could not be obtained for anastomotic hemorrhage and thromboembolic. When it is injected into the lumen of small diameter, poloxamer is insufficient strength, it was considered to be insufficient as a guide to ensure lumen.