为了无创地测量包括深主动脉在内的人体动脉的弹性特性,我们研制了一种与截面回波描记术相连接的新型回波跟踪装置。该装置对脉动直径变化(D)的精度<delta><10^(-3)> mm,对直径(D)的精度约为0.5mm,足以测量动脉壁的粘弹性。用该超声装置无创测量了61例健康人(20-89岁)腹主动脉的压力应变弹性模量(Ep),从<delta>D、D和听诊法测得的血压。平均Ep值为2.1 x <10^6>达因/ <cm^2>。Ep随年龄增长而显著增加(p<0.001),回归方程为Ep=(-0.72+0.058 ×年龄)× 10^6达因/cm ~ 2(r=0.73)。在对4名健康人主动脉至肱动脉和腘动脉的动脉树弹性特性的系统测量中, ...更多信息 Ep值在动脉外周部位升高。在年龄匹配的42名健康受试者和32名冠状动脉疾病(CAD)患者(40-60岁)的测量中,Ep分别为0.99和1.83 x <10^6> dyne/ <cm^2>。冠心病患者腹主动脉的狭窄程度也明显高于正常人(P<0.001)。冠心病患者Ep值与血总胆固醇值呈显著正相关(P<0.01)。加速因素如冠状动脉危险因素被怀疑也会影响主动脉硬化的进展。此外,利用该装置并结合导管尖端微压计测量血压,通过计算机系统,从压力-半径关系中的滞后回线面积获得了14例受试者在体主动脉的粘弹性。测得的粘度系数(<eta>)为2.34 x <10^6>达因·s/ <cm ^2>,粘性损耗模量(<eta><omega>)为1.83 x <10^6>达因/ <cm ^2>,相位角(<phi>)为0.087弧度,Ep为2.02 x <10^6>达因/ <cm ^2>。少
英文摘要
To measure noninvasively the elastic properties of in vivo human arteries including deep aorta, which had not been able to be measured hitherto, a new echo tracking device linked to cross-sectional echography was deyeloped. The accuracy of the device for pulsatile diameter change( <delta> D) was <10^(-3)> mm and for diameter(D) was around 0.5mm respectively, and was sufficient to measure the visco-elastic properties of arterial wall. The pressure strain elastic modulus (Ep) of the abdominal aorta were noninvasively measured in 61 healthy subjects(20-89 years) with this ultrasonic device from <delta> D, D and blood pressure obtained by auscultatory method. The mean Ep value was 2.1 x <10^6> dyne/ <cm^2> . Ep was significantly increased with age(p<0.001), The regression equation relating Ep to age was Ep=(-0.72+0.058 x age)x <10^6> dyne/ <cm^2> (r=0.73). In the systemic measurement of elastic properties in arterial tree from aorta to brachial and popliteal artery in 4 healthy subjects, t … More he elevation of Ep value was found in the peripheral site of the artery. In the measurement of age-matched 42 healthy subjects and 32 patients with coronary artery disease(CAD)(40-60 years), Ep was 0.99 and 1.83 x <10^6> dyne/ <cm^2> respectively. A significant sclerotic change(p<0.001) was found also in the abdominal aorta in CAD patients compared with normal subjects. A significant correlation(p<0.01) between Ep value and the value of blood total cholesterol was found in the CAD patients. Accelerating factor like a coronary risk factor was suspected to influence also the progression of aortic sclerosis. Furthermore, with the device and the additional use of catherter tip micromanometer for blood pressure measurement, visco-elastic properties of aorta in vivo were obtained in 14 subjects from the area of the hysteresis loop in the pressure-radius relationship with computer system. Coefficient of viscosity( <eta> ) 2.34 x <10^4> dyne.s/ <cm^2> , viscous loss modulus( <eta> <omega> ) 1.83 x <10^6> dyne/ <cm^2> , and phase angle( <phi> ) 0.087 radian, Ep 2.02 x <10^6> dyne/ <cm^2> were obtained. Less
期刊论文(6)
专著(0)
科研奖励(0)
会议论文
登录
查看更多内容
北海道医学雑誌. 60-5. (1985)
北海道医学杂志。60-5。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Atherosclerosis. (1986)
动脉粥样硬化。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
New Method for Detection Ischemic Heart Cell Damage
-
批准号:63870037
-
项目类别:Grant-in-Aid for Developmental Scientific Research (B).
-
资助金额:$5.95万
-
财政年份:1988
-
负责人:YASUDA Hisakazu
-
依托单位:
海外基金