Collision of cold ions stored in an electrostatic ion storage ring
Collision of cold ions stored in an electrostatic ion storage ring
批准号:
14204062
负责人:
SHINOMARU Haruo
金额:
$35.69万
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (A)
财政年份:
2002
资助国家:
日本
项目状态:
已结题
起止时间:
2002 至 2005
中文摘要
东京都立大学作为第一个液氮冷却的E环,建造了静电离子储存环(TMU E环),成功地储存了包括亚稳态离子和大分子离子在内的各种离子。与现有的E环、奥胡斯的ELISA和KEK的ESRING相比,同时存储了不同质量的各种离子,并且凭借本研究开发的尺寸选择性束处理技术,存储、喷射特定离子。成束、去成束或加速。正如ELISA小组所证明的那样,电子环是研究长寿命亚稳态离子的理想装置,它能在几毫秒到几秒内储存离子。本文测量了双电荷CO_2的寿命。为了拟合测量的衰变曲线,需要至少三个衰变分量。关于大分子离子,富勒烯和卟啉阴离子产生的激光解吸源存储在环中。研究了卟啉阴离子的激光诱导电子脱离,重点关注延迟电子发射。中性产额的时间曲线不符合t-1依赖性,这是广泛接受的内部热离子的衰变曲线。这些结果表明,光激发的阴离子的能量分布将不同于从离子源中提取的“热”离子,并且对激发方式相当敏感。通过扫描激发波长,首次测量了气相阴离子的吸收光谱。
英文摘要
An electrostatic ion storage ring (TMU E-ring) was constructed in Tokyo Metropolitan University as a first LN2-cooled E-ring, and various ions including metastable ions and large molecular ions were successfully stored. In contrast to the existing E-rings, ELISA at Aarhus and ESRING at KEK, various ions with different masses were stored simultaneously, and by virtue of size-selective beam-handling techniques developed in the present study, specific ions were stored, ejected, bunched, de-bunched, or accelerated.As demonstrated by the ELISA group, E-ring is a suitable device for the study of long-life metastable ions it can store ions in several milliseconds to seconds. In the present study, lifetime of doubly charged CO_2 was measured. To fit the measured decay curve, at least three decay components were needed. Concerning large molecular ions, fullerene and porphyrin anions generated in a laser desorption source were stored in the ring. Laser-induced electron detachment of porphyrin anions was studied focusing attention onto delayed electron emission. Time profile of the neutral yield was not well fitted by t-1 dependence, which is widely accepted for the decay profile of internally hot ions. These results indicate that the energy distribution of the photo-excited anions would be different from "hot" ions extracted from the ion source, and quite sensitive to the way of excitation. By scanning excitation wavelength, absorption spectra of gas-phase anions were also measured for the first time.
期刊论文(111)
专著(0)
科研奖励(0)
会议论文
登录
查看更多内容
Mobility of NO^+ in helium gas at 77 K and 4.3 K
77 K 和 4.3 K 时 NO^ 在氦气中的迁移率
DOI:
--
发表时间:
2003
期刊:
J. Phys. B : At. Mol. Opt. Phys. 36
影响因子:
--
作者:
[Wakakuwa M, Arikawa K, Ozaki K, H.Hidaka 他3名]
通讯作者:
H.Hidaka 他3名
Geminate Ion Kinetics for Hexa-, Penta- and Tetrachloroethane in Liquid Methylcyclohexane (MCH) : Effect of the Anion Lifetimes
液体甲基环己烷 (MCH) 中六氯乙烷、五氯乙烷和四氯乙烷的双离子动力学:阴离子寿命的影响
DOI:
--
发表时间:
2003
期刊:
J. Phys. Chem. A 107(51)
影响因子:
--
作者:
[軍司昌秀, 中西博昭, 鷲津正夫, M.A.Quadir 他4名]
通讯作者:
M.A.Quadir 他4名
S.Jinno他9名: "TMU electrostatic ion storage ring designed for operation at liquid nitrogen temperature"Nuclear Instrum.Methods in Phys.Research, A,. (in press).
S. Jinno 和其他 9 人:“TMU 静电离子存储环设计用于在液氮温度下运行”Nuclear Instrum.Methods in Phys.Research,A,(出版中)。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Collision dynamics of MCI-molecule systems studied by multi-coincidence technique
通过多重符合技术研究 MCI 分子系统的碰撞动力学
DOI:
--
发表时间:
2005
期刊:
Nucl. Instrum. & Methods B235
影响因子:
--
作者:
[T Kaneyasu 他2名]
通讯作者:
T Kaneyasu 他2名
低温ヘリウム気体中のイオン移動度
低温氦气中的离子淌度
DOI:
--
发表时间:
2004
期刊:
日本物理学会誌 59
影响因子:
--
作者:
[田沼肇]
通讯作者:
田沼肇
共 42 条
海外基金