Development of biological monitoring methods of heat strain for preventing a heat stroke.
Development of biological monitoring methods of heat strain for preventing a heat stroke.
批准号:
15590567
负责人:
TSUTSUI Takao
金额:
$1.54万
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (C)
财政年份:
2003
资助国家:
日本
项目状态:
已结题
起止时间:
2003 至 2004
中文摘要
我们研究了一种生物学监测热应激反应的方法,以防止工人在炎热的环境中工作。我们选择一个音响频道来测量核心温度。“听觉运河被一个耳塞堵塞以减少外部气候影响。”在人工气候室内控制在25、30、35 ° C,湿度为60%,六名男性志愿者被要求在75 ° C的运动中进行三次重复20分钟,在自行车温度计上休息15分钟。试验室的温度是用耳插头型热传感器测量的。放射性温度在稳定的环境温度条件下具有一个相关性,与audititory canal温度有一个相关性。例如,环境温度变化到热或冷方向, auditory canal温度也变化到热或冷点依赖于环境温度。从25 ° C到35 ° C在环境条件下,在0.6 ° C中的低温温度和试验室温度的差异。然后,我们用微型热数据记录仪测量了实验室的温度。27名工作人员在四个车间用热传感器覆盖耳插头连接到微型数据记录仪,在炎热的环境中工作。我们还通过视觉模拟量表(VAS)对工作前和工作后的工作人员进行了热感应和张力的询问。auditory canal温度的峰值和平均值与热感和张力VAS值的总和有关。We think that the peak value of the auditory canal temperature shows the exposure limit of heat strain and the mean value of the auditory canal temperature shows the exposure dose of the heat strain。这是有可能的,因为音响公司运河温度的峰值和平均值可能是预防热浪的有效指标。
英文摘要
We investigate the biological monitoring methods of heat strain for preventing a heat stroke among workers working in the hot environment. We choose an auditory canal to measure a core temperature. The auditory canal was insulated with an ear plug to reduce external climate effects. In the artificial climate chamber controlled at 25, 30, 35゜C and humidity 60%, six male volunteers were asked to perform three repeats of 20 min of 75 W exercise and 15 min rest on the bicycle ergometer. Auditory canal temperature was measured using an ear plug type thermo-sensor. Rectal temperature had a correlation with auditory canal temperature under stable environmental temperature condition. However, environmental temperature changes to hot or cold direction, auditory canal temperature also changes to hot or cold point depending on the environmental temperature. From 25゜C to 35゜C in environmental condition, the difference of rectal temperature and auditory canal temperature was within 0.6゜C. Then we measured the auditory canal temperature among workers using a mini thermo data logger. Twenty-seven workers in the four workshops wore the ear plug with thermo sensor connected to the mini data logger, worked in the hot environment. We also asked the questionnaire to the workers about heat sensation and tiredness by visual analog scale (VAS) before and after the job. Peak and mean value of the auditory canal temperature had correlation with sum of the heat sensation and tiredness VAS value. We think that the peak value of the auditory canal temperature shows the exposure limit of heat strain and the mean value of the auditory canal temperature shows the exposure dose of the heat strain. It is possible that the peak and mean value of the auditory canal temperature might be the effective indexes for preventing a heat stroke.
期刊论文(15)
专著(0)
科研奖励(0)
会议论文
登录
查看更多内容
Body cooling capacity of water circulated cooling pants during lower body exercise in a hot environment
炎热环境下半身运动时水循环降温裤的身体降温能力
DOI:
--
发表时间:
2005
期刊:
J UOEH 27(1)
影响因子:
--
作者:
[Saito, T., Furukawa, T., Nanri, S., Saito, I., 小池眞規子, Yoichi Hirakata, Takao Tsutsui]
通讯作者:
Takao Tsutsui
筒井隆夫: "暑熱環境下でのエルゴメータによる繰り返し運動負荷における下肢用冷却服の効果"産業衛生学雑誌 第45巻臨時増刊号. 45巻. 545 (2003)
Takao Tsutsui:“在炎热环境中使用测力计冷却下肢衣物的效果”《工业卫生杂志》第 45 卷特刊(2003 年)。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
暑熱作業における送風式冷却服の効果
通风式降温服在高温作业中的作用
DOI:
--
发表时间:
2005
期刊:
産業衛生学雑誌 47(臨時増刊)
影响因子:
--
作者:
[川瀬洋平, 藤井ロナウド, 永野千景 他]
通讯作者:
永野千景 他
耳栓で遮断された外耳道温の実験的検討
耳塞阻塞外耳道温度的实验研究
DOI:
--
发表时间:
2004
期刊:
産業衛生学雑誌 46巻・臨時増刊号
影响因子:
--
作者:
[筒井隆夫, 井戸田望, 堀江正知他]
通讯作者:
堀江正知他
耳栓で遮蔽された外耳道温の労働現場への応用
耳塞耳道温度屏蔽在工作场所的应用
DOI:
--
发表时间:
2004
期刊:
産業衛生学雑誌 46(臨時増刊)
影响因子:
--
作者:
[井戸田望, 筒井隆夫, 堀江正知 他]
通讯作者:
堀江正知 他
共 10 条
Evaluation of low back pain factors by measuring the planter pressure.
-
批准号:20590665
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$3.0万
-
财政年份:2008
-
负责人:TSUTSUI Takao
-
依托单位:
海外基金