Development of a 4Mhz suprasternal Doppler probe for cardiac output measurement
Development of a 4Mhz suprasternal Doppler probe for cardiac output measurement
批准号:
720663
负责人:
金额:
$21.47万
依托单位:
依托单位国家:
英国
项目类别:
GRD Development of Prototype
财政年份:
2015
资助国家:
英国
项目状态:
已结题
起止时间:
2015 至 --
中文摘要
心输出量(CO)是指每分钟泵出的血液量,其准确测量对临床医生评估心血管功能和体液状态至关重要。目前有几种侵入性和非侵入性技术可用于确定CO;然而,这些技术在准确性和适用性方面存在局限性。Deltex Medical(Deltex)目前制造了一种使用4 MHz超声食管多普勒监测仪(ODM)评估CO的领先技术。该技术是高度精确的,并已被广泛证明可以改善患者的预后。然而,探针被放置到食管中,这可能引发“呕吐反射”。因此,清醒患者对食管探针的耐受性不佳。为了解决这个问题,Deltex旨在开发一种基于多普勒超声的无创CO测量系统,可以无创地应用于胸骨上切迹。Deltex和竞争对手(USCOM)之前都采用了这种方法,使用可重复使用的探针,导致产品无菌性和高资本成本问题(见创新问题)。因此,Deltex计划使用一次性4 MHz探头开发胸骨上超声技术。这的主要附加优势是与公司现有的已安装显示器库兼容。该技术将主要针对手术和重症监护中使用的增强恢复计划,成功将减少住院时间和相关的健康成本,然后将CO测量扩展到新部门(例如心脏病学,A&E,运动医学等)。到目前为止,Deltex已经进行了一项试点研究,以确定最佳多普勒频率,解剖目标和开始验证技术参数,如头部尺寸和信号分辨率。随着预生产原型和临床试验的预期发展,Deltex预计5年内的累计销售额至少为1000万英镑。
英文摘要
The accurate measurement of Cardiac Output (CO), the volume of blood pumped/min, iscritical for clinicians to assess cardiovascular function & fluid status. Several invasive & noninvasive techniques are currently available to determine CO; however these possesslimitations with accuracy & suitability for use in all patient types. Deltex Medical (Deltex)currently manufactures a leading technology to assess CO using a 4MHz ultrasoundOesophageal Doppler Monitor (ODM). The technology is highly precise & has been widelydemonstrated to improve patient outcome. However the probe is placed into the oesophaguswhich can initiate a ‘gag reflex’. The oesophageal probe is therefore not well tolerated inawake patients. To address this issue, Deltex aims to develop a non invasive CO measurementsystem based on Doppler ultrasound that can be applied non-invasively at the suprasternalnotch. Such an approach has been adopted previously by both Deltex & a competitor(USCOM) using a reusable probe, resulting in issues with product sterility & high capitalcosts (see innovation question). Therefore, Deltex intends to develop the suprasternalultrasound technique using a disposable 4 MHz probe. This has the major added advantage ofbeing compatible with the company’s existing installed monitor base. The technology willinitially be targeted towards the Enhanced Recovery Programme used in surgery, & inintensive care, where success will reduce the length of hospital stay & associated healthcarecosts, & then extend CO measurement for use in new departments (e.g. cardiology, A&E,sports medicine, etc.). To date, Deltex has undertaken a pilot study to identify the optimalDoppler frequency, anatomical targets & begin verification of technical parameters such ashead size & signal resolution. With the intended development of the pre-production prototype& a clinical trial, Deltex expects accumulated sales of at least £10M over 5yrs.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文