IMPROVED ULTRASONIC IMAGING VIA SYSTEM IDENTIFICATION
IMPROVED ULTRASONIC IMAGING VIA SYSTEM IDENTIFICATION
批准号:
2285477
负责人:
CARLOS E DAVILA
金额:
$3.95万
依托单位国家:
美国
项目类别:
财政年份:
1996
资助国家:
美国
项目状态:
已结题
起止时间:
1996-07-01 至 2000-09-30
中文摘要
描述(改编自申请人摘要):当前超声成像
英文摘要
DESCRIPTION (Adapted from applicant's abstract): Current ultrasonic imaging
technology results in images which, despite advances in transducer
technology, still contain a high level of distortion. The ultrasonic image
is obtained by measuring the reflections of an ultrasound wavelet
transmitted from a transducer positioned on the skin. Depth variations in
the acoustic impedance of subdermal tissues produce reflections which can be
used to image tissue boundaries. Distortion in the lateral direction,
perpendicular to the propagation path of the ultrasound, is due to
diffraction spreading of the ultrasound beam and can be compensated by using
phased arrays to focus and steer the main ultrasonic beam in the desired
direction. Another significant source of distortion in ultrasonic images
occurs on the axial direction, along the ultrasound propagation path, and is
due to reverberation resulting from a convolution of the outgoing ultrasonic
wavelet with the intervening tissue reflection profile. Most attempts at
compensating for axial distortion have involved some form of deconvolution
where the reflected signal is filtered by an inverse filter in an attempt to
increase the axial resolution of the image. There are a number of problems
inherent in the deconvolution approach which have been well-documented.
These include unrealizable inverse filters due to non-minimum phase
wavelets, a high sensitivity to noise, unrealistic assumptions about tissue
and transducer characteristics, and a statistical stationarity requirement -
implying that deconvolution does not readily lend itself to imaging
time-varying tissue structures. The method proposed here addresses these
problems by using adaptive system identification to measure ultrasonic
images. The significance of this approach is that, unlike deconvolution
methods, system identification makes no assumptions about the tissue or
transducer characteristics, and is much less susceptible to noise. The
system identification concept is also particularly well suited for
time-varying tissue structures. A new system identification algorithm is
described which is particularly well-suited for this task given its high
insensitivity to measurement noise. Equipment for setting up an ultrasound
imaging lab is sought. The equipment includes ultrasound transducers, a
pulser/receiver for exciting the transducer and conditioning the received
ultrasound, a water tank for holding the transducer and target, an assembly
that allows very accurate control of transducer/target position, and a
digital oscilloscope for doing high speed data acquisition and display.
This research seeks to improve the axial resolution of A-mode scans using
system identification. Long-term plans call for extending the system
identification concept to B-scans and phased array technology.