沿海湿热耦合作用下型钢混凝土组合柱劣化机理研究
批准号:
52078138
项目类别:
面上项目
资助金额:
58.0 万元
负责人:
陈誉
依托单位:
学科分类:
结构工程
结题年份:
2024
批准年份:
2020
项目状态:
已结题
项目参与者:
陈誉
中文摘要
针对沿海湿热耦合作用下型钢混凝土组合柱劣化严重这一突出工程问题,以该环境下长服役周期型钢混凝土构件破坏机理与性能评价为目标,利用现场采样、细观测试、环境模型建立、力学性能测试和有限元数值分析等研究手段,深入研究沿海高温高湿环境和结构荷载的长效耦合作用,探明该服役条件下型钢混凝土组合柱静、动力性能随时间演化规律。选取沿海高温高湿环境样本和既有长服役周期型钢混凝土结构样本,提炼代表性环境参数、材性参数以及构件几何参数;建立沿海湿热耦合环境模型;标定实验室加速模拟方案并根据方案对型钢混凝土组合柱进行环境加速处理;开展型钢混凝土组合柱劣化后静、动力性能研究。剖析沿海湿热耦合作用下型钢混凝土组合柱的传力特性及破坏模式,构建损伤后型钢混凝土组合柱的基本力学模型;提出适用于该类服役条件下型钢混凝土组合柱的性能评价方法及失效判别准则,并给出考虑沿海湿热耦合作用的型钢混凝土组合柱承载力计算方法。
英文摘要
Aiming at the prominent engineering problem of severe degradation of steel reinforced concrete composite columns under the effect of coastal humidity-heat coupling, in-situ sampling, meso-testing, environmental model building, mechanical property testing, and finite element numerical analysis are used to deeply study the long-term coupling effects of high-temperature and high-humidity environments along the coast. The evolution of static and dynamic performance of steel reinforced concrete composite columns with time under this service condition is proved. And the failure mechanism and performance evaluation of long service life steel reinforced concrete members in this environment are targeted. Samples of coastal high-temperature and high-humidity environment samples and existing long-service period steel reinforced concrete structures were selected to extract representative environmental parameters, material properties parameters, and component geometric parameters. The model of coastal humidity-heat coupling environment is established. According to the calibrated scheme, the steel reinforced concrete composite columns are treated with environmental acceleration. And the static and dynamic properties of steel concrete composite columns after deterioration are studied. This research analyzes the force transmission characteristics and failure modes of steel reinforced concrete composite columns under the effect of humidity and heat coupling along the coast, and constructs the basic mechanical model of steel reinforced concrete composite columns after damage. The performance evaluation method and failure criterion for steel reinforced concrete composite columns suitable for this type of service conditions are proposed, and the calculation method of bearing capacity of steel reinforced concrete composite columns considering humidity and heat coupling effect along the coast is given.
针对沿海湿热环境下型钢混凝土组合柱的劣化问题,结合现场采样、细观测试、环境模型、力学性能测试和数值分析,系统研究了长服役周期内型钢混凝土构件的破坏机理与性能劣化规律,揭示了型钢-混凝土粘结界面的腐蚀劣化机理,建立了沿海湿热耦合作用下型钢混凝土组合柱的基本力学模型。主要研究工作及结论如下:.(1) 开展了型钢柱的通电加速腐蚀试验和轴向压缩试验,揭示了腐蚀对型钢柱力学性能的劣化影响。基于试验结果,验证了数值模拟方法的准确性,提出了氯盐环境中型钢柱极限承载力计算公式。提出了一种随机腐蚀坑生成算法,能够有效模拟实际腐蚀坑分布,并精准预测型钢柱的极限承载力。.(2) 针对钢-混凝土粘结界面开展了模拟加速腐蚀试验和推出试验,探讨了典型参数对钢-混凝土粘结界面的影响规律,揭示了钢-混凝土粘结区域在腐蚀条件下的劣化机理。考虑粘结机制和腐蚀损伤,提出了界面极限粘结应力和残余粘结应力计算模型。基于不同腐蚀程度下粘结特性,构建了钢与混凝土粘结界面四阶段粘结-滑移本构劣化模型,为腐蚀环境下钢-混凝土数值模拟提供了依据。.(3) 开展了型钢-混凝土组合柱在人工加速环境腐蚀(盐雾腐蚀、电化学腐蚀、海洋暴露腐蚀)劣化试验,揭示了型钢-混凝土组合柱在轴向压缩荷载下的力学性能劣化规律。基于改进的多物理场数值模型,解决了多介质真实腐蚀环境的重构和全景再现的关键技术难题。建立了型钢-混凝土组合结构承载力劣化预测模型,为完善腐蚀环境基础设施的耐久性研究及设计方法提供了理论参考。.(4) 开展了型钢-混凝土组合构件电化学加速腐蚀和拟静力试验,揭示了腐蚀组合构件在低周往复荷载作用下的典型失效模式、滞回性能和时变抗震性能劣化规律。基于X射线衍射(XRD)分析和钨灯丝电子显微镜(SEM)扫描,阐明了腐蚀组合构件混凝土保护层的锈胀开裂机理和损伤演化规律,为完善沿海地震区型钢-混凝土组合结构的全寿命抗震性能评估体系提供理论支撑。
拉挤型GFRP管-混凝土-型钢组合柱受力性能与设计方法研究
-
批准号:51778066
-
项目类别:面上项目
-
资助金额:62.0万元
-
批准年份:2017
-
负责人:陈誉
-
依托单位:
国内基金
海外基金