Effect of impaction sequence on osteochondral graft damage: the role of repeated and varying loads.

Effect of impaction sequence on osteochondral graft damage: the role of repeated and varying loads.
复制标题

DOI:
10.1177/0363546509349038
复制
发表时间:
2010-01
期刊:
The American journal of sports medicine
影响因子:
--
通讯作者:
Wimmer MA
Wimmer MA
中科院分区:
其他
文献类型:
--
作者:
Kang RW;Friel NA;Williams JM;Cole BJ;Wimmer MA

文献摘要

参考文献

被引文献

相似文献

Osteochondral autografts and allografts require mechanical force for proper graft placement into the defect site; however, impaction compromises the tissue. This study aimed to determine the effect of impaction force and number of hits to seat the graft on cartilage integrity. Under constant impulse conditions, higher impaction load magnitudes are more detrimental to cell viability, matrix integrity and collagen network organization and will result in proteoglycan loss and nitric oxide release. Controlled laboratory study Osteochondral explants, harvested from fresh bovine trochleas, were exposed to a series of consistent impact loads delivered by a pneumatically driven device. Each plug received the same overall impulse of 7 Ns, reflecting the mean of 23 clinically inserted plugs. Impaction loads of 37.5N, 75N, 150N, and 300N were matched with 74, 37, 21, and 11 hits respectively. Following impaction, the plugs were harvested and cartilage was analyzed for cell viability, histology by safranin-o and picosirius red, and release of sulfated glycosaminoglycans and nitric oxide. Data were compared with non-impacted control. Impacted plugs had significantly lower cell viability than non-impacted plugs. A dose response relationship in loss of cell viability with respect to load magnitude was seen immediately and after 4 days but lost after 8 days. Histologic analysis revealed intact cartilage surface in all samples (loaded or control), with loaded samples showing alterations in birefringence. While the sulfated GAG release was similar across varying impaction loads, release of nitric oxide increased with increasing impaction magnitudes and time. Impaction loading parameters have a direct effect on the time course of the viability of the cartilage in the graft tissue. Optimal loading parameters for surgical impaction of osteochondral grafts are those with lower load magnitudes and a greater number of hits to ensure proper fit.
DOI: 10.1016/s0736-0266(03)00039-1
发表时间: 2003-09-01
影响因子: 2.8
作者:
Lewis, JL;Deloria, LB;Oegema, TR
通讯作者: Oegema, TR
DOI: 10.1177/0363546504263945
发表时间: 2004-09-01
影响因子: 4.8
作者:
Lane, JG;Massie, JB;Amiel, D
通讯作者: Amiel, D
DOI: 10.1177/0363546505274578
发表时间: 2005-03-01
影响因子: 4.8
作者:
Alford, JW;Cole, BJ
通讯作者: Cole, BJ
DOI: 10.1016/j.jbiomech.2004.04.016
发表时间: 2005-03-01
影响因子: 2.4
作者:
Milentijevic, D;Torzilli, PA
通讯作者: Torzilli, PA
DOI: 10.1006/abbi.1995.1439
发表时间: 1995-09-10
影响因子: 3.9
作者:
JEFFREY, JE;GREGORY, DW;ASPDEN, RM
通讯作者: ASPDEN, RM