Accurate detection of carcinoma cells by use of a cell microarray chip.
Accurate detection of carcinoma cells by use of a cell microarray chip.
复制标题
DOI:
10.1371/journal.pone.0032370
复制
发表时间:
2012
期刊:
影响因子:
3.7
通讯作者:
Kataoka M
中科院分区:
文献类型:
--
作者:
Yamamura S;Yatsushiro S;Yamaguchi Y;Abe K;Shinohara Y;Tamiya E;Baba Y;Kataoka M
Accurate detection and analysis of circulating tumor cells plays an important role in the diagnosis and treatment of metastatic cancer treatment. A cell microarray chip was used to detect spiked carcinoma cells among leukocytes. The chip, with 20,944 microchambers (105 µm width and 50 µm depth), was made from polystyrene; and the formation of monolayers of leukocytes in the microchambers was observed. Cultured human T lymphoblastoid leukemia (CCRF-CEM) cells were used to examine the potential of the cell microarray chip for the detection of spiked carcinoma cells. A T lymphoblastoid leukemia suspension was dispersed on the chip surface, followed by 15 min standing to allow the leukocytes to settle down into the microchambers. Approximately 29 leukocytes were found in each microchamber when about 600,000 leukocytes in total were dispersed onto a cell microarray chip. Similarly, when leukocytes isolated from human whole blood were used, approximately 89 leukocytes entered each microchamber when about 1,800,000 leukocytes in total were placed onto the cell microarray chip. After washing the chip surface, PE-labeled anti-cytokeratin monoclonal antibody and APC-labeled anti-CD326 (EpCAM) monoclonal antibody solution were dispersed onto the chip surface and allowed to react for 15 min; and then a microarray scanner was employed to detect any fluorescence-positive cells within 20 min. In the experiments using spiked carcinoma cells (NCI-H1650, 0.01 to 0.0001%), accurate detection of carcinoma cells was achieved with PE-labeled anti-cytokeratin monoclonal antibody. Furthermore, verification of carcinoma cells in the microchambers was performed by double staining with the above monoclonal antibodies. The potential application of the cell microarray chip for the detection of CTCs was shown, thus demonstrating accurate detection by double staining for cytokeratin and EpCAM at the single carcinoma cell level.
登录
查看更多内容
DOI:
10.1186/bcr2131
发表时间:
2008
期刊:
Breast cancer research : BCR
影响因子:
--
作者:
Deng G;Herrler M;Burgess D;Manna E;Krag D;Burke JF
通讯作者:
Burke JF
影响因子:
3.8
作者:
Mostert, Bianca;Kraan, Jaco;Sleijfer, Stefan
通讯作者:
Sleijfer, Stefan
影响因子:
7.4
作者:
Yamamura, S;Kishi, H;Muraguchi, A
通讯作者:
Muraguchi, A
影响因子:
3.7
作者:
Yatsushiro S;Yamamura S;Yamaguchi Y;Shinohara Y;Tamiya E;Horii T;Baba Y;Kataoka M
通讯作者:
Kataoka M
影响因子:
10.3
作者:
Sieuwerts, Anieta M.;Kraan, Jaco;Bolt, Joan;van der Spoel, Petra;Elstrodt, Fons;Schutte, Mieke;Martens, John W. M.;Gratama, Jan-Willem;Sleijfer, Stefan;Foekens, John A.
通讯作者:
Foekens, John A.