Fasting pyloric diameter and distensibility by functional endoluminal imaging probe in unsedated healthy volunteers.
Fasting pyloric diameter and distensibility by functional endoluminal imaging probe in unsedated healthy volunteers.
复制标题
DOI:
10.1111/nmo.14386
复制
发表时间:
2022-10
影响因子:
3.5
通讯作者:
Camilleri, Michael
中科院分区:
文献类型:
--
作者:
Zheng, Ting;Vosoughi, Kia;Busciglio, Irene;Tebay, Lisa;Burton, Duane;Camilleri, Michael
Recent studies with functional endoluminal imaging probe (EndoFLIP®) measure physiologic characteristics of the pylorus. EndoFLIP® has the potential to select optimal candidates for gastric peroral endoscopic myotomy (G-POEM). Normative values of the pylorus using EndoFLIP® have not been established. 24 healthy volunteers (20–56 years old; 15 females) underwent unsedated, transoral EndoFLIP® measurements of the pylorus after 8 hours of fasting. Measurements of diameter (DM), balloon pressure, and distensibility index (DI) of the pylorus were obtained twice over 5 minutes at 40, 50, and 60mL balloon distensions. Pyloric DM at 40, 50, and 60mL balloon distensions were 13.0±2.5, 14.3±1.8, and 17.2±2.0 mm, respectively. DM with 60mL distension was notably higher than with 40 and 50mL distensions. Pyloric DI at 40, 50, and 60mL distensions were 10.9±4.8, 11.3±5.8, and 11.1±4.3 mm2/mm Hg, respectively (P=0.86). Linear regression and Bland-Altman plots showed similar distribution of the DM and DI during the second minute compared to the full 5-minute measurements at 50mL distension, as well as between two sequential measurements using 50mL distension. With 50mL balloon distension, intraindividual coefficients of variation (COVintra) for DM and DI were 13.8% and 29.6%, respectively and interindividual COV (COVinter) were 12.6% and 51.3%, respectively. Similar reproducibility was obtained with 40mL balloon distension. Unsedated EndoFLIP® can be used to characterize human fasting pyloric diameter and distensibility, with best performance observed with 40mL and 50mL distensions and data collection during the second minute. Normative values reported serve as reference values for future studies. EndoFLIP® was used to characterize fasting pyloric diameter and distensibility in unsedated healthy volunteers. Stable measurements were observed at 2 minutes after balloon distension with optimal volume of 40–50mL.
登录
查看更多内容
影响因子:
2.6
作者:
Conchillo JM;Straathof JWA;Mujagic Z;Brouns JH;Bouvy ND;Keszthelyi D;Masclee AAM
通讯作者:
Masclee AAM
影响因子:
24.5
作者:
Vosoughi, Kia;Ichkhanian, Yervant;Khashab, Mouen
通讯作者:
Khashab, Mouen
影响因子:
5.7
作者:
Inada, T;Asai, T;Shingu, K
通讯作者:
Shingu, K
影响因子:
7.7
作者:
Vosoughi, Kia;Ichkhanian, Yervant;Khashab, Mouen A.
通讯作者:
Khashab, Mouen A.
影响因子:
3.1
作者:
Jehangir, Asad;Malik, Zubair;Parkman, Henry P.
通讯作者:
Parkman, Henry P.