Cardiac implantable electronic devices in adults with tetralogy of Fallot.

Cardiac implantable electronic devices in adults with tetralogy of Fallot.
复制标题

DOI:
10.1136/heartjnl-2018-314072
复制
发表时间:
2019-04
期刊:
Heart (British Cardiac Society)
影响因子:
--
通讯作者:
Connolly HM
Connolly HM
中科院分区:
其他
文献类型:
--
作者:
Egbe AC;Miranda WR;Madhavan M;Ammash NM;Missula VR;Al-Otaibi M;Fatola A;Kothapalli S;Connolly HM

文献摘要

参考文献

被引文献

相似文献

tachyarrhythmias and bradyarrhythmias affect 20%–50% of adult patients with tetralogy of Fallot (TOF) and some of these patients will require cardiac implantable electronic devices (CIED) such as pacemaker and/or internal cardioverter defibrillator. the Mayo adult congenital heart Disease database was queried for patients with repaired TOF and history of CIED implantation, 1990–2017. The study objectives were: (1) determine the occurrence of device-related complications defined as lead failure, lead recall, device infection and lead thrombus; and (2) determine the occurrence and risk factors for defibrillator shock. there were 99 patients (age 46±14 years and 66 (66%) men) with CIED, and the CIEDs were 41 (41%) pacemakers and 73 (73%) defibrillators. indication for defibrillator implantation was for primary prevention in 28 (38%) and secondary prevention in 45 (62%). Device-related complications occurred in 20 (20%) patients (lead failure 17, lead recall 4, device infection 12 and thrombus 3). Twenty-five per cent of all device infections occurred within 30 days from the time of device generator change. Annualised rates of appropriate and inappropriate shocks were 5.7% and 6.2%, respectively. The use of class III antiarrhythmic drug was protective against defibrillator shock. the current study provides useful outcome data to aid patient counselling and clinical decision-making. Further studies are required to explore ways to decrease the risk of postprocedural infection after device generator change, and to determine which patients will benefit from empirical antiarrhythmic therapy as a strategy to decrease incidence of inappropriate defibrillator shock.
DOI: 10.1161/01.cir.0000138397.60956.c2
发表时间: 2004-09-14
期刊: CIRCULATION
影响因子: 37.8
作者:
Frigiola, A;Redington, AN;Vogel, M
通讯作者: Vogel, M
DOI: 10.1016/j.jacc.2013.09.033
发表时间: 2014-01-21
影响因子: 24
作者:
Janson, Christopher M.;Patel, Akash R.;Shah, Maully J.
通讯作者: Shah, Maully J.
DOI: 10.1016/s0735-1097(02)02344-6
发表时间: 2002-11-06
影响因子: 24
作者:
Ghai, A;Silversides, C;Therrien, J
通讯作者: Therrien, J
DOI: 10.1136/heartjnl-2013-304958
发表时间: 2014-02
期刊: Heart (British Cardiac Society)
影响因子: --
作者:
Valente AM;Gauvreau K;Assenza GE;Babu-Narayan SV;Schreier J;Gatzoulis MA;Groenink M;Inuzuka R;Kilner PJ;Koyak Z;Landzberg MJ;Mulder B;Powell AJ;Wald R;Geva T
通讯作者: Geva T
DOI: 10.1161/circulationaha.109.928481
发表时间: 2010-08-31
期刊: CIRCULATION
影响因子: 37.8
作者:
Khairy, Paul;Aboulhosn, Jamil;Broberg, Craig S.
通讯作者: Broberg, Craig S.