Pixel-wise assessment of cardiovascular magnetic resonance first-pass perfusion using a cardiac phantom mimicking transmural myocardial perfusion gradients.
Pixel-wise assessment of cardiovascular magnetic resonance first-pass perfusion using a cardiac phantom mimicking transmural myocardial perfusion gradients.
复制标题
DOI:
10.1002/mrm.28296
复制
发表时间:
2020-11
影响因子:
3.3
通讯作者:
Chiribiri A
中科院分区:
文献类型:
--
作者:
Milidonis X;Nazir MS;Schneider T;Capstick M;Drost S;Kok G;Pelevic N;Poelma C;Schaeffter T;Chiribiri A
Cardiovascular magnetic resonance first-pass perfusion for the pixel-wise detection of coronary artery disease is rapidly becoming the clinical standard, yet no widely available method exists for its assessment and validation. This study introduces a novel phantom capable of generating spatially dependent flow values to enable assessment of new perfusion imaging methods at the pixel level. A synthetic multicapillary myocardial phantom mimicking transmural myocardial perfusion gradients was designed and manufactured with high-precision 3D printing. The phantom was used in a stationary flow setup providing reference myocardial perfusion rates and was scanned on a 3T system. Repeated first-pass perfusion MRI for physiological perfusion rates between 1 and 4 mL/g/min was performed using a clinical dual-sequence technique. Fermi function-constrained deconvolution was used to estimate pixel-wise perfusion rate maps. Phase contrast (PC)-MRI was used to obtain velocity measurements that were converted to perfusion rates for validation of reference values and cross-method comparison. The accuracy of pixel-wise maps was assessed against simulated reference maps. PC-MRI indicated excellent reproducibility in perfusion rate (coefficient of variation [CoV] 2.4-3.5%) and correlation with reference values (R2 = 0.985) across the full physiological range. Similar results were found for first-pass perfusion MRI (CoV 3.7-6.2%, R2 = 0.987). Pixel-wise maps indicated a transmural perfusion difference of 28.8-33.7% for PC-MRI and 23.8-37.7% for first-pass perfusion, matching the reference values (30.2-31.4%). The unique transmural perfusion pattern in the phantom allows effective pixel-wise assessment of first-pass perfusion acquisition protocols and quantification algorithms before their introduction into routine clinical use.
登录
查看更多内容
影响因子:
10.6
作者:
Gabrani-Juma, Hanif;Clarkin, Owen J.;Klein, Ran
通讯作者:
Klein, Ran
影响因子:
14
作者:
Mordini, Federico E.;Haddad, Tariq;Hsu, Li-Yueh;Kellrnan, Peter;Lowrey, Tracy B.;Aletras, Anthony H.;Bandettini, Patricia;Arai, Andrew E.
通讯作者:
Arai, Andrew E.
DOI:
10.1016/j.jcmg.2018.12.022
发表时间:
2019-10
期刊:
JACC. Cardiovascular imaging
影响因子:
--
作者:
Kotecha T;Martinez-Naharro A;Boldrini M;Knight D;Hawkins P;Kalra S;Patel D;Coghlan G;Moon J;Plein S;Lockie T;Rakhit R;Patel N;Xue H;Kellman P;Fontana M
通讯作者:
Fontana M
影响因子:
6.4
作者:
Brown, Louise A. E.;Onciul, Sebastian C.;Plein, Sven
通讯作者:
Plein, Sven
影响因子:
3.8
作者:
Driscoll, B.;Keller, H.;Coolens, C.
通讯作者:
Coolens, C.