Ligase detection reaction for the analysis of point mutations using free-solution conjugate electrophoresis in a polymer microfluidic device.
Ligase detection reaction for the analysis of point mutations using free-solution conjugate electrophoresis in a polymer microfluidic device.
复制标题
DOI:
10.1002/elps.200800197
复制
发表时间:
2008-12
期刊:
影响因子:
2.9
通讯作者:
Soper, Steven A.
中科院分区:
文献类型:
--
作者:
Sinville, Rondedrick;Coyne, Jennifer;Meayher, Robert J.;Cheng, Yu-Wei;Barany, Francis;Barron, Annelise;Soper, Steven A.
关键词:
We have developed a new method for the analysis of low abundant point mutations in genomic DNA using a combination of an allele-specific ligase detection reaction (LDR) with free-solution conjugate electrophoresis (FSCE) to generate and analyze the genetic products. FSCE eliminates the need for a polymer sieving matrix by conjugating chemically synthesized polyamide “drag-tags” onto the LDR primers. The additional drag of the charge-neutral drag-tag breaks the linear scaling of the charge-to-friction ratio of DNA and enables size-based separations of DNA in free solution using electrophoresis with no sieving matrix. We successfully demonstrate the conjugation of polyamide drag-tags onto a set of four LDR primers designed to probe the K-ras oncogene for mutations highly associated with colorectal cancer, the simultaneous generation of fluorescently-labeled LDR/drag-tagged (LDR-dt) products in a multiplexed, single-tube format with mutant:wild-type ratios as low as 1:100, respectively, and the single-base, high-resolution separation of all four LDR-dt products. Separations were conducted in free solution with no polymer network using both a commercial capillary array electrophoresis (CAE) system and a poly(methylmethacrylate), PMMA, microchip replicated via hot-embossing with only a Tris-based running buffer containing additives to suppress the electroosmotic flow (EOF). Typical analysis times for LDR-dt conjugates were 11 min using the CAE system and as low as 85 s for the PMMA microchips. With resolution comparable to traditional gel-based CAE, FSCE along with microchip electrophoresis decreased the separation time by more than a factor of 40.
登录
查看更多内容
影响因子:
2.8
作者:
Hupert, Mateusz L.;Guy, W. Jason;Soper, Steven A.
通讯作者:
Soper, Steven A.
DOI:
10.1073/pnas.0507904102
发表时间:
2005-11-08
影响因子:
11.1
作者:
Diehl, F;Li, M;Vogelstein, B
通讯作者:
Vogelstein, B
影响因子:
5.6
作者:
Gerry, NP;Witowski, NE;Barany, F
通讯作者:
Barany, F
影响因子:
14.9
作者:
Luo, JY;Bergstrom, DE;Barany, F
通讯作者:
Barany, F
影响因子:
2.2
作者:
Rothschild, CB;Brewer, CS;Triscott, MX
通讯作者:
Triscott, MX