A comprehensive electromagnetic evaluation of an MRI anthropomorphic head phantom.

A comprehensive electromagnetic evaluation of an MRI anthropomorphic head phantom.
复制标题

磁共振成像人头模型的综合电磁评估。

DOI:
10.1002/nbm.4441
复制
发表时间:
2021-03
期刊:
影响因子:
2.9
通讯作者:
Ibrahim TS
Ibrahim TS
中科院分区:
医学3区
文献类型:
--
作者:
Wood S;Santini T;Krishnamurthy N;Martins T;Farhat N;Ibrahim TS

文献摘要

参考文献

相似文献

a recently developed six-compartment refillable 3D-printed anthropomorphic head phantom (developed from MRI scans obtained in vivo), where the phantom itself is filled in its entirety with either heterogeneous loading, or homogeneous brain or water loading, in vivo imaging, and a commercial homogeneous spherical water phantom. Electromagnetic simulations are an important tool for the safety assessment of RF coils. They are a useful resource for MRI RF coil designers, especially when complemented with experimental measurements and testing using physical phantoms. Regular-shaped (spherical/cylindrical) homogeneous phantoms are the MRI standard for RF testing but are somewhat inaccurate when compared with anthropomorphic anatomies, especially at high frequencies. In this work, using a recently developed anthropomorphic heterogeneous human head phantom, studies were performed to analyze the scattering parameters (S-parameters) and the electric and magnetic field distributions using (1) the B1+ field mapping method on a 7 T human MRI scanner and (2) numerical full-wave electromagnetic simulations. All studies used the following: Our results determined that the calculated S-parameters for all the anthropomorphic head phantom models were comparable to the model that is based on the volunteer (within 17% difference of the reflection coefficient value) but differed for the commercial homogeneous spherical water phantom (within 45% difference). The experimentally measured B1+ field maps of the anthropomorphic heterogeneous and homogeneous brain head phantoms were most comparable to the in vivo measured values. The numerical simulations also show that both the anthropomorphic homogeneous water and brain phantom models were less accurate in terms of electric field intensities/distributions when compared with the segmented in-vivo-based head model and the anthropomorphic heterogeneous head phantom model. The presented data highlights the differences between the physical phantoms/phantom models, and the in vivo measurements/segmented in-vivo-based head model. The results demonstrate the usefulness of 3D-printed anthropomorphic phantoms for RF coil evaluation and testing.
DOI: 10.1002/mrm.25123
发表时间: 2015-01
影响因子: 3.3
作者:
Graedel, Nadine N.;Polimeni, Jonathan R.;Guerin, Bastien;Gagoski, Borjan;Wald, Lawrence L.
通讯作者: Wald, Lawrence L.
DOI: 10.1002/jmri.20919
发表时间: 2007-06-01
影响因子: 4.4
作者:
Ibrahim, Tamer S.;Tang, Lin
通讯作者: Tang, Lin
DOI: 10.1002/bem.2250130609
发表时间: 1992-01-01
影响因子: 1.9
作者:
GANDHI, OP;GAO, BQ;CHEN, JY
通讯作者: CHEN, JY
DOI: 10.1002/jmri.24152
发表时间: 2014-02
期刊: Journal of magnetic resonance imaging : JMRI
影响因子: --
作者:
Krishnamurthy N;Zhao T;Ibrahim TS
通讯作者: Ibrahim TS
DOI: 10.1088/0031-9155/42/3/003
发表时间: 1997-03-01
影响因子: 3.5
作者:
Dimbylow, PJ
通讯作者: Dimbylow, PJ