The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis.

The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis.
复制标题

通过皮肤色素沉着水平测量氧饱和度在测量氧饱和度中的准确性:系统的综述和荟萃分析。

DOI:
10.1186/s12916-022-02452-8
复制
发表时间:
2022-08-16
期刊:
影响因子:
9.3
通讯作者:
Cullum, Nicky
Cullum, Nicky
中科院分区:
医学1区
文献类型:
--
作者:
Shi, Chunhu;Goodall, Mark;Dumville, Jo;Hill, James;Norman, Gill;Hamer, Oliver;Clegg, Andrew;Watkins, Caroline Leigh;Georgiou, George;Hodkinson, Alexander;Lightbody, Catherine Elizabeth;Dark, Paul;Cullum, Nicky

文献摘要

参考文献

被引文献

相似文献

During the COVID-19 pandemic, there have been concerns regarding potential bias in pulse oximetry measurements for people with high levels of skin pigmentation. We systematically reviewed the effects of skin pigmentation on the accuracy of oxygen saturation measurement by pulse oximetry (SpO2) compared with the gold standard SaO2 measured by CO-oximetry. We searched Ovid MEDLINE, Ovid Embase, EBSCO CINAHL, ClinicalTrials.gov, and WHO International Clinical Trials Registry Platform (up to December 2021) for studies with SpO2–SaO2 comparisons and measuring the impact of skin pigmentation or ethnicity on pulse oximetry accuracy. We performed meta-analyses for mean bias (the primary outcome in this review) and its standard deviations (SDs) across studies included for each subgroup of skin pigmentation and ethnicity and used these pooled mean biases and SDs to calculate accuracy root-mean-square (Arms) and 95% limits of agreement. The review was registered with the Open Science Framework (https://osf.io/gm7ty). We included 32 studies (6505 participants): 15 measured skin pigmentation and 22 referred to ethnicity. Compared with standard SaO2 measurement, pulse oximetry probably overestimates oxygen saturation in people with the high level of skin pigmentation (pooled mean bias 1.11%; 95% confidence interval 0.29 to 1.93%) and people described as Black/African American (1.52%; 0.95 to 2.09%) (moderate- and low-certainty evidence). The bias of pulse oximetry measurements for people with other levels of skin pigmentation or those from other ethnic groups is either more uncertain or suggests no overestimation. Whilst the extent of mean bias is small or negligible for all subgroups evaluated, the associated imprecision is unacceptably large (pooled SDs > 1%). When the extent of measurement bias and precision is considered jointly, pulse oximetry measurements for all the subgroups appear acceptably accurate (with Arms < 4%). Pulse oximetry may overestimate oxygen saturation in people with high levels of skin pigmentation and people whose ethnicity is reported as Black/African American, compared with SaO2. The extent of overestimation may be small in hospital settings but unknown in community settings. https://osf.io/gm7ty The online version contains supplementary material available at 10.1186/s12916-022-02452-8.
DOI: 10.1017/s1047951119001355
发表时间: 2019-08-01
影响因子: 1
作者:
Harris, Bronwyn U.;Stewart, Sarah;Ramamoorthy, Chandra
通讯作者: Ramamoorthy, Chandra
DOI: 10.1097/pcc.0000000000000660
发表时间: 2016-04-01
影响因子: 4.1
作者:
Harris, Bronwyn U.;Char, Danton S.;Ramamoorthy, Chandra
通讯作者: Ramamoorthy, Chandra
DOI: 10.1097/00000542-200504000-00004
发表时间: 2005-04-01
期刊: ANESTHESIOLOGY
影响因子: 8.8
作者:
Bickler, PE;Feiner, JR;Severinghaus, JW
通讯作者: Severinghaus, JW
DOI: 10.1016/j.resuscitation.2006.11.018
发表时间: 2007-07-01
期刊: RESUSCITATION
影响因子: 6.5
作者:
Hinkelbein, Jochen;Koehler, Heike;Fiedler, Fritz
通讯作者: Fiedler, Fritz
DOI: 10.1016/j.resuscitation.2006.06.024
发表时间: 2007-01-01
期刊: RESUSCITATION
影响因子: 6.5
作者:
Hinkelbein, Jochen;Genzwuerker, Harald V.;Fiedler, Fritz
通讯作者: Fiedler, Fritz