Investigations of organ and effective doses of abdominal cone-beam computed tomography during transarterial chemoembolization using Monte Carlo simulation.

Investigations of organ and effective doses of abdominal cone-beam computed tomography during transarterial chemoembolization using Monte Carlo simulation.
复制标题

DOI:
10.1186/s12880-018-0247-7
复制
发表时间:
2018-02-05
影响因子:
2.7
通讯作者:
Lui KW
Lui KW
中科院分区:
医学4区
文献类型:
--
作者:
Hwang YS;Tsai HY;Lin YY;Lui KW

文献摘要

参考文献

被引文献

相似文献

To investigate the organ dose, effective dose (ED), conversion factor, and the C-arm rotation angle effects on dose variations of abdominal C-arm cone-beam computed tomography (CBCT) during transarterial chemoembolization (TACE). The organ doses and EDs for abdominal C-arm CBCT were retrospectively calculated according to a Monte Carlo technique for 80 patients. Dose variations from projections, ED to dose–area product (DAP) ratios, and effects of body mass index (BMI) on the ED and ED to DAP ratios were also analyzed. The kidney received the highest dose (14.6 ± 1.2 mSv). Organ dose deviations among C-arm rotation angles was highest for stomach (CV = 0.71). The mean ED of the the CBCT run during TACE was 3.5 ± 0.5 mSv, and decreased with increased BMI (R2 = 0.45, p < 0.001). The mean ED to DAP ratio was 0.27 ± 0.04 mSv·Gy− 1·cm− 2 and tended to decrease with increased BMI (R2 = 0.55, p < 0.001). The mean ED to DAP ratios were 0.29 ± 0.02, 0.26 ± 0.02, and 0.23 ± 0.03 mSv·Gy− 1·cm− 2 for patients with BMI < 25 kg/m2, 25–30 kg/m2, and ≥30 kg/m2, respectively. Suitable conversion factors for C-arm CBCT facilitate the use of DAPs for estimating the ED. The patient dose can be varied by adjusting the CBCT rotation angle setting, and dose reduction strategies can be further manipulated.
DOI: 10.1016/j.jvir.2008.02.002
发表时间: 2008-06-01
影响因子: 2.9
作者:
Orth, Robert C.;Wallace, Michael J.;Kuo, Michael D.
通讯作者: Kuo, Michael D.
DOI: 10.1007/s00270-010-9893-z
发表时间: 2011-04-01
影响因子: 2.9
作者:
Suzuki, Shigeru;Yamaguchi, Ichiro;Ozaki, Yutaka
通讯作者: Ozaki, Yutaka
DOI: 10.1148/radiol.2502080695
发表时间: 2009-02-01
期刊: RADIOLOGY
影响因子: 19.7
作者:
Suzuki, Shigeru;Furui, Shigeru;Kobayashi, Ikuo
通讯作者: Kobayashi, Ikuo
DOI: 10.1016/j.jvir.2011.02.011
发表时间: 2011-04-01
影响因子: 2.9
作者:
Braak, Sicco J.;van Strijen, Marco J. L.;van Heesewijk, Johannes P. M.
通讯作者: van Heesewijk, Johannes P. M.
DOI: 10.1016/j.jacc.2007.03.040
发表时间: 2007-07-17
影响因子: 24
作者:
Ector, Joris;Dragusin, Octavian;Heidbuechel, Hein
通讯作者: Heidbuechel, Hein