Studies on quantitative phosphopeptide analysis by matrix-assisted laser desorption/ionization mass spectrometry without label, chromatography or calibration curves.
Studies on quantitative phosphopeptide analysis by matrix-assisted laser desorption/ionization mass spectrometry without label, chromatography or calibration curves.
复制标题
DOI:
10.1002/rcm.7063
复制
发表时间:
2014-12-30
影响因子:
2
通讯作者:
Chang, Emmanuel J.
中科院分区:
文献类型:
--
作者:
Ho, Hsin-Pin;Rathod, Pratikkumar;Louis, Marissa;Tada, Christine K.;Rahaman, Sherida;Mark, Kevin J.;Leng, Jin;Dana, Dibyendu;Kumar, Sanjai;Lichterfeld, Mathias;Chang, Emmanuel J.
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry combined with isotope labeling methods are effective for protein and peptide quantification, but limited in their multiplexing capacity, cost-effectiveness and dynamic range. This study investigates MALDI MS-based quantification of peptide phosphorylation without labeling, and aims to overcome the shot-to-shot variability of MALDI using a mathematical transformation and extended data acquisition times. A linear relationship between the reciprocal of phosphopeptide mole fraction and the reciprocal of phosphorylated-to-unphosphorylated signal ratio is derived, and evaluated experimentally using three separate phosphopeptide systems containing phosphorylated serine, threonine and tyrosine residues: mixtures of phosphopeptide and its des-phospho-analog with known stoichiometry measured by vacuum MALDI-linear ion trap mass spectrometry and fit to the linear model. The model is validated for quantifying in vitro phosphorylation assays with inhibition studies on Cdk2/cyclinA. Dynamic range of picomoles to femtomoles, good accuracy (deviations of 1.5–3.0% from expected values) and reproducibility (RSD = 4.3–6.3%) are achieved. Inhibition of Cyclin-dependent Kinase phosphorylation by the classical inhibitors olomoucine and r-roscovitine was evaluated and IC50 values found to be in agreement with reported literature values. These results, achieved with single-point calibration, without isotope or chromatography, compare favorably to those arrived at using isotope dilution (p > 0.5 for accuracy). The mathematical relationship derived here can be applied to a method that we term Double Reciprocal Isotope-free Phosphopeptide Quantification (DRIP-Q), as a strategy for quantification of in vitro phosphorylation assays, the first MALDI-based, isotope- and calibration curve-free method of its type. These results also pave the way for further systematic studies investigating the effect of peptide composition and experimental conditions on quantitative, label-free MALDI.
登录
查看更多内容
影响因子:
30.3
作者:
Leng J;Ho HP;Buzon MJ;Pereyra F;Walker BD;Yu XG;Chang EJ;Lichterfeld M
通讯作者:
Lichterfeld M
影响因子:
4.4
作者:
Wang, Hongxia;Alvarez, Sophie;Hicks, Leslie M.
通讯作者:
Hicks, Leslie M.
影响因子:
3.4
作者:
Asara, John M.;Christofk, Heather R.;Cantley, Lewis C.
通讯作者:
Cantley, Lewis C.
影响因子:
7
作者:
Boersema, Paul J.;Foong, Leong Yan;Heck, Albert J. R.
通讯作者:
Heck, Albert J. R.
影响因子:
--
作者:
Jia, Yong;Quinn, Christopher M;Talanian, Robert V
通讯作者:
Talanian, Robert V