Polymeric microsphere enhanced surface plasmon resonance imaging immunosensor for occult blood monitoring
Polymeric microsphere enhanced surface plasmon resonance imaging immunosensor for occult blood monitoring
复制标题
用于潜血监测的聚合物微球增强表面等离子共振成像免疫传感器
DOI:
10.1016/j.snb.2021.130858
复制
发表时间:
2022-01
期刊:
影响因子:
--
通讯作者:
Yonghong Shao
中科院分区:
文献类型:
--
作者:
Jie Zhou;Xueliang Wang;Jiajie Chen;Youjun Zeng;Dayong Gu;Bruce Zhi Gao;Yonghong Shao
Occult blood testing is a routine screening method for evaluating the function of the urinary system and digestive tract. The hemoglobin (Hb) content in human excreta is an important indicator of the presence of occult blood. In this study, a surface plasmon resonance imaging (SPRi)-based immunosensor with high sensitivity was developed for the detection of Hb. The immunosensor was constructed by physically immobilizing anti-Hb antibodies on the detection channels. Samples for evaluation were pre-incubated with the polymeric microsphere-antibody conjugate. The shift in resonance wavelength induced by the specific binding of microsphere-antibody-antigen and immobilized antibodies was monitored in real time. Owing to the amplification effect of microspheres, the detection limit of the immunosensor was reduced 42-fold to 4.8 ng/mL under the optimized concentration of immobilized antibody (10 μg/mL) with microsphere-antibody conjugate dilution ratio of 1:200 and incubation time of the microsphere-antibody conjugate and samples (10 min). The immunosensor displayed a good linear response to Hb ranging from 10 ng/mL to 500 ng/mL in both test solutions and in 1:30 urine sample, as well as a good specificity toward Hb and an acceptable recovery rate for spiked Hb solution in urine sample. The immunosensor was also exploited to detect the Hb concentration in 50 clinical urine samples. Therefore, the proposed SPRi immunosensor developed in this study provides a simple, rapid, high-throughput, and sensitive immunology strategy for the detection of occult blood.
登录
查看更多内容
DOI:
10.1086/375896
发表时间:
2003-08
期刊:
Clinical infectious diseases : an official publication of the Infectious Diseases Society of America
影响因子:
--
作者:
C. Gill;J. Lau;S. Gorbach;D. Hamer
通讯作者:
C. Gill;J. Lau;S. Gorbach;D. Hamer
影响因子:
3.8
作者:
Lee, Sang Hun;Sung, Jong Hwan;Park, Tai Hyun
通讯作者:
Park, Tai Hyun
影响因子:
4.8
作者:
N. Swaminathan;Yowan Nerthigan;Hui-Fen Wu
通讯作者:
N. Swaminathan;Yowan Nerthigan;Hui-Fen Wu
DOI:
10.3760/cma.j.issn.1009-9158.2017.04.016
发表时间:
2017-04
影响因子:
--
作者:
Ping Wang;Hui Liu;Tie Zhang
通讯作者:
Ping Wang;Hui Liu;Tie Zhang
影响因子:
3.7
作者:
Garcés-Chávez, V;Quidant, R;Dholakia, K
通讯作者:
Dholakia, K