Comparative Monte Carlo study on the performance of integration- and list-mode detector configurations for carbon ion computed tomography
Comparative Monte Carlo study on the performance of integration- and list-mode detector configurations for carbon ion computed tomography
复制标题
碳离子计算机断层扫描积分模式和列表模式探测器配置性能的比较蒙特卡罗研究
DOI:
10.1088/1361-6560/aa5602
复制
发表时间:
2017
影响因子:
3.5
通讯作者:
Parodi K
中科院分区:
文献类型:
--
作者:
Meyer S;Gianoli C;Magallanes L;Kopp B;Tessonnier T;Landry G;Dedes G;Voss B;Parodi K
Ion beam therapy offers the possibility of a highly conformal tumor-dose distribution; however, this technique is extremely sensitive to inaccuracies in the treatment procedures. Ambiguities in the conversion of Hounsfield units of the treatment planning x-ray CT to relative stopping power (RSP) can cause uncertainties in the estimated ion range of up to several millimeters. Ion CT (iCT) represents a favorable solution allowing to directly assess the RSP. In this simulation study we investigate the performance of the integration-mode configuration for carbon iCT, in comparison with a single-particle approach under the same set-up. The experimental detector consists of a stack of 61 air-filled parallel-plate ionization chambers, interleaved with 3 mm thick PMMA absorbers. By means of Monte Carlo simulations, this design was applied to acquire iCTs of phantoms of tissue-equivalent materials. An optimization of the acquisition parameters was performed to reduce the dose exposure, and the implications of a reduced absorber thickness were assessed. In order to overcome limitations of integration-mode detection in the presence of lateral tissue heterogeneities a dedicated post-processing method using a linear decomposition of the detector signal was developed and its performance was compared to the list-mode acquisition. For the current set-up, the phantom dose could be reduced to below 30 mGy with only minor image quality degradation. By using the decomposition method a correct identification of the components and a RSP accuracy improvement of around 2.0% was obtained. The comparison of integration-and list-mode indicated a slightly better image quality of the latter, with an average median RSP error below 1.8% and 1.0%, respectively. With a decreased absorber thickness a reduced RSP error was observed. Overall, these findings support the potential of iCT for low dose RSP estimation, showing that integration-mode detectors with dedicated post-processing strategies can provide a RSP accuracy comparable to list-mode configurations.
登录
查看更多内容
DOI:
--
发表时间:
2016
期刊:
影响因子:
--
作者:
C. Gianoli;S. Meyer;L. Magallanes;G. Dedes;G. Landry;R. Nijhuis;U. Ganswindt;C. Thieke;C. Belka;K. Parodi
通讯作者:
K. Parodi
影响因子:
19.7
作者:
WILSON, RR
通讯作者:
WILSON, RR
DOI:
--
发表时间:
2000
期刊:
影响因子:
--
作者:
C. Brusasco;B. Voss;D. Schardt;M. Krämer;G. Kraft
通讯作者:
G. Kraft
影响因子:
3.5
作者:
Rinaldi I;Brons S;Jäkel O;Voss B;Parodi K
通讯作者:
Parodi K
DOI:
--
发表时间:
2014
期刊:
Physica medica (Testo stampato)
影响因子:
--
作者:
Katia Parodi
通讯作者:
Katia Parodi