Phase II safety and clinical comparison with single-photon emission computed tomography myocardial perfusion imaging for detection of coronary artery disease: flurpiridaz F 18 positron emission tomography.

Phase II safety and clinical comparison with single-photon emission computed tomography myocardial perfusion imaging for detection of coronary artery disease: flurpiridaz F 18 positron emission tomography.
复制标题

DOI:
10.1016/j.jacc.2012.11.022
复制
发表时间:
2013-01-29
影响因子:
24
通讯作者:
Washburn, Dana
Washburn, Dana
中科院分区:
医学1区
文献类型:
--
作者:
Berman, Daniel S.;Maddahi, Jamshid;Tamarappoo, B. K.;Czernin, Johannes;Taillefer, Raymond;Udelson, James E.;Gibson, C. Michael;Devine, Marybeth;Lazewatsky, Joel;Bhat, Gajanan;Washburn, Dana

文献摘要

参考文献

被引文献

相似文献

II期试验,旨在评估氟吡达兹F 18的安全性,并比较其在PET心肌灌注成像(MPI)与Tc-99 m SPECT-MPI中的诊断性能,包括图像质量、解释确定性、缺陷程度和有创冠状动脉造影(伊卡)中冠状动脉疾病(CAD)(≥ 50%狭窄)的检测。在临床前和I期研究中,氟吡达兹F 18显示出基本上理想的MPI示踪剂的特征。来自21个中心的143名患者接受了静息负荷PET和Tc-99 m SPECT-MPI。86例患者接受了伊卡,39例患者的CAD可能性较低。由3名独立的盲法阅片员对图像进行评分。PET与SPECT在负荷(99.2% vs. 88.5%,p<0.01)和静息(96.9% vs. 66.4,p<0.01)图像上的图像被评定为优/良的百分比更高。PET与SPECT的诊断解释确定性(明确异常/正常解释的病例%)更高(90.8% vs. 70.9%,p<0.01)。在86例接受伊卡的患者中,PET的灵敏度高于SPECT [分别为78.8%和61.5%(p=0.02)]。特异性无显著差异(PET:76.5% vs. SPECT:73.5%)。PET和SPECT的受试者工作特征曲线面积分别为0.82±0.05和0.70±0.06(p=0.04)。PET和SPECT的正常率分别为89.7%和97.4%(p=NS)。在伊卡上的CAD患者中,PET的可逆性缺损程度大于SPECT(p=0.008)。广泛的安全性评估显示,氟吡哒唑F18在该队列中是安全的。在这项II期试验中,使用氟吡达兹F 18的PET MPI是安全的,并且在图像质量、解释确定性和总体CAD诊断方面优于SPECT MPI上级。
Phase II trial to assess flurpiridaz F 18 for safety and compare its diagnostic performance for PET myocardial perfusion imaging (MPI) to Tc-99m SPECT-MPI regarding image quality, interpretative certainty, defect magnitude and detection of coronary artery disease (CAD)(≥ 50% stenosis) on invasive coronary angiography (ICA). In preclinical and phase I studies, flurpiridaz F 18 has shown characteristics of an essentially ideal MPI tracer. 143 patients from 21 centers underwent rest-stress PET and Tc-99m SPECT-MPI. Eighty-six patients underwent ICA, and 39 had low-likelihood of CAD. Images were scored by 3 independent, blinded readers. A higher % of images were rated as excellent/good on PET vs. SPECT on stress (99.2% vs. 88.5%, p<0.01) and rest (96.9% vs. 66.4, p<0.01) images. Diagnostic certainty of interpretation (% cases with definitely abnormal/normal interpretation) was higher for PET vs. SPECT (90.8% vs. 70.9%, p<0.01). In 86 patients who underwent ICA, sensitivity of PET was higher than SPECT [78.8% vs. 61.5%, respectively (p=0.02)]. Specificity was not significantly different (PET:76.5% vs. SPECT:73.5%). Receiver operating characteristic curve area was 0.82±0.05 for PET and 0.70±0.06 for SPECT (p=0.04). Normalcy rate was 89.7% with PET and 97.4% with SPECT (p=NS). In patients with CAD on ICA, the magnitude of reversible defects was greater with PET than SPECT (p=0.008). Extensive safety assessment revealed that flurpiridaz F 18 was safe in this cohort. In this Phase 2 trial, PET MPI using flurpiridaz F 18 was safe and superior to SPECT MPI for image quality, interpretative certainty, and overall CAD diagnosis.
DOI: 10.1161/01.cir.63.6.1259
发表时间: 1981-01-01
期刊: CIRCULATION
影响因子: 37.8
作者:
SCHELBERT, HR;PHELPS, ME;KUHL, DE
通讯作者: KUHL, DE
DOI: 10.1093/ejechocard/jen321
发表时间: 2009-01-01
影响因子: --
作者:
Senior, Roxy;Monaghan, Mark;Picard, Michael H.
通讯作者: Picard, Michael H.
DOI: 10.1016/j.nuclcard.2007.07.008
发表时间: 2007-11-01
影响因子: 2.4
作者:
Yu, Ming;Guaraldi, Mary T.;Robinson, Simon P.
通讯作者: Robinson, Simon P.
DOI: 10.1161/01.cir.91.3.813
发表时间: 1995-02-01
期刊: CIRCULATION
影响因子: 37.8
作者:
GLOVER, DK;RUIZ, M;BELLER, GA
通讯作者: BELLER, GA