Speciation analysis of urine iodine by ion-pair reversed-phase liquid chromatography and inductively coupled plasma mass spectrometry

Speciation analysis of urine iodine by ion-pair reversed-phase liquid chromatography and inductively coupled plasma mass spectrometry
复制标题

离子对反相液相色谱和电感耦合等离子体质谱法分析尿碘形态

DOI:
10.1039/c4ay00396a
复制
发表时间:
2014-06
期刊:
影响因子:
3.1
通讯作者:
Xu, Zigang
Xu, Zigang
中科院分区:
化学3区
文献类型:
--
作者:
Sun, Jiannan;Cheng, Heyong;Liu, Jinhua;Xu, Zigang

文献摘要

参考文献

被引文献

相似文献

本文介绍了离子对反相液相色谱-电感耦合等离子体质谱法(RP-LC-ICP-MS)在尿液中碘形态分析中的应用。考虑到绿色分析化学和Ar ICP-MS仪器的要求,采用3种水流动相分离碘化物、碘酸盐和5种碘氨基酸(单碘酪氨酸- MIT、二碘酪氨酸- DIT、三碘甲状腺原氨酸- T3、逆三碘甲状腺原氨酸- rT3、甲状腺素- T4)。水流动相由离子对试剂(四丁基氢氧化铵- TBAH)和洗脱液(氯化铵、l -苯丙氨酸或脱氧胆酸)在超纯水中的低浓度组成。由于这些碘化形式之间的保留行为存在巨大差异,采用梯度洗脱模式分别对IO3 -和I -、MIT和DIT、T3、rT3和T4进行了快速分离。用12.5 mm C18保护柱在7 min内完成碘的分离。检测限分别为0.047、0.046、0.057、0.072、0.093、0.094和0.081 μg L−1。通过对四个实际尿样中碘的形态分析,验证了该方法的应用。该方法回收率在93 ~ 106%范围内,重复性好,在环境、食品和生物样品中碘形态的常规分析中具有较大的应用潜力。
This work described the utilization of ion-pair reversed phase liquid chromatography coupled to inductively coupled plasma mass spectrometry (RP-LC-ICP-MS) for iodine speciation analysis in urine. Considering the requirements of green analytical chemistry and the Ar ICP-MS instrument, three aqueous mobile phases were employed for the separation of seven iodine species including iodide, iodate and five iodo amino acids (monoiodotyrosine – MIT, di-iodotyrosine – DIT, tri-iodothyronine – T3, reversed tri-iodothyronine – rT3, and thyroxine – T4). The aqueous mobile phases were composed of an ion-pair reagent (tetrabutylammonium hydroxide – TBAH) and an eluent (ammonium chloride, L-phenylalanine or deoxycholic acid) at low concentrations in ultrapure water. Owing to tremendous difference in retention behavior between these iodinated forms, a gradient elution mode was performed for the rapid separation of IO3− and I−, MIT and DIT, and T3, rT3 and T4, respectively. Iodine species separation was achieved with a 12.5 mm C18 guard column in 7 min. The detection limits for IO3−, I−, MIT, DIT, T3, rT3 and T4 were 0.047, 0.046, 0.057, 0.072, 0.093, 0.094 and 0.081 μg L−1, respectively. Application of the proposed method was demonstrated by the speciation analysis of iodine in four real urine samples. The developed method offered satisfactory recoveries in the 93–106% range and good repeatability, showing great potential in routine analysis of iodine speciation in environmental, food and biological samples.
DOI: 10.1039/c0ja00270d
发表时间: 2011-09
影响因子: 3.4
作者:
Jian Zheng;M. Yamada;S. Yoshida
通讯作者: Jian Zheng;M. Yamada;S. Yoshida
DOI: 10.1016/j.talanta.2007.02.014
发表时间: 2007-07-31
期刊: TALANTA
影响因子: 6.1
作者:
Chen, ZuLiang;Megharaj, Mallavarapu;Naidu, Ravendra
通讯作者: Naidu, Ravendra
DOI: 10.1039/c0ja00272k
发表时间: 2011-11
影响因子: 3.4
作者:
A. Moreda-Piñeiro;V. Romarís-Hortas;P. Bermejo-Barrera
通讯作者: A. Moreda-Piñeiro;V. Romarís-Hortas;P. Bermejo-Barrera
DOI: 10.1021/ac00054a018
发表时间: 1993-03
影响因子: 7.4
作者:
K. Takatera;Tadashi Watanabe
通讯作者: K. Takatera;Tadashi Watanabe
DOI: 10.1016/s0048-9697(97)00182-4
发表时间: 1997-10-01
影响因子: 9.8
作者:
Hou, XL;Chai, CF;Fan, X
通讯作者: Fan, X