4D motion modeling of the coronary arteries from CT images for robotic assisted minimally invasive surgery
4D motion modeling of the coronary arteries from CT images for robotic assisted minimally invasive surgery
复制标题
根据 CT 图像对冠状动脉进行 4D 运动建模,用于机器人辅助微创手术
DOI:
10.1117/12.811518
复制
发表时间:
2009
期刊:
影响因子:
--
通讯作者:
Zhang D
中科院分区:
文献类型:
--
作者:
Zhang D
In this paper, we present a novel approach for coronary artery motion modeling from cardiac Computed Tomography( CT) images. The aim of this work is to develop a 4D motion model of the coronaries for image guidance in robotic-assisted totally endoscopic coronary artery bypass (TECAB) surgery. To utilize the pre-operative cardiac images to guide the minimally invasive surgery, it is essential to have a 4D cardiac motion model to be registered with the stereo endoscopic images acquired intraoperatively using the da Vinci robotic system. In this paper, we are investigating the extraction of the coronary arteries and the modelling of their motion from a dynamic sequence of cardiac CT. We use a multi-scale vesselness filter to enhance vessels in the cardiac CT images. The centerlines of the arteries are extracted using a ridge traversal algorithm. Using this method the coronaries can be extracted in near real-time as only local information is used in vessel tracking. To compute the deformation of the coronaries due to cardiac motion, the motion is extracted from a dynamic sequence of cardiac CT. Each timeframe in this sequence is registered to the end-diastole timeframe of the sequence using a non-rigid registration algorithm based on free-form deformations. Once the images have been registered a dynamic motion model of the coronaries can be obtained by applying the computed free-form deformations to the extracted coronary arteries. To validate the accuracy of the motion model we compare the actual position of the coronaries in each time frame with the predicted position of the coronaries as estimated from the non-rigid registration. We expect that this motion model of coronaries can facilitate the planning of TECAB surgery, and through the registration with real-time endoscopic video images it can reduce the conversion rate from TECAB to conventional procedures.
影响因子:
10.6
作者:
Frangi, AF;Niessen, WJ;Viergever, MA
通讯作者:
Viergever, MA
DOI:
10.1007/bfb0056195
发表时间:
1998-01-01
期刊:
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI'98
影响因子:
--
作者:
Frangi, AF;Niessen, WJ;Viergever, MA
通讯作者:
Viergever, MA
DOI:
10.1007/978-3-540-75757-3_41
发表时间:
2007
期刊:
Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention
影响因子:
--
作者:
R. Chandrashekara;R. Mohiaddin;R. Razavi;D. Rueckert
通讯作者:
D. Rueckert