Arterial elasticity imaging: comparison of finite-element analysis models with high-resolution ultrasound speckle tracking.

Arterial elasticity imaging: comparison of finite-element analysis models with high-resolution ultrasound speckle tracking.
复制标题

DOI:
10.1186/1476-7120-8-22
复制
发表时间:
2010-06-18
影响因子:
1.9
通讯作者:
Weitzel WF
Weitzel WF
中科院分区:
医学4区
文献类型:
--
作者:
Park DW;Richards MS;Rubin JM;Hamilton J;Kruger GH;Weitzel WF

文献摘要

参考文献

被引文献

相似文献

The nonlinear mechanical properties of internal organs and tissues may be measured with unparalleled precision using ultrasound imaging with phase-sensitive speckle tracking. The many potential applications of this important noninvasive diagnostic approach include measurement of arterial stiffness, which is associated with numerous major disease processes. The accuracy of previous ultrasound measurements of arterial stiffness and vascular elasticity has been limited by the relatively low strain of nonlinear structures under normal physiologic pressure and the measurement assumption that the effect of the surrounding tissue modulus might be ignored in both physiologic and pressure equalized conditions. This study performed high-resolution ultrasound imaging of the brachial artery in a healthy adult subject under normal physiologic pressure and the use of external pressure (pressure equalization) to increase strain. These ultrasound results were compared to measurements of arterial strain as determined by finite-element analysis models with and without a surrounding tissue, which was represented by homogenous material with fixed elastic modulus. Use of the pressure equalization technique during imaging resulted in average strain values of 26% and 18% at the top and sides, respectively, compared to 5% and 2%, at the top and sides, respectively, under physiologic pressure. In the artery model that included surrounding tissue, strain was 19% and 16% under pressure equalization versus 9% and 13% at the top and sides, respectively, under physiologic pressure. The model without surrounding tissue had slightly higher levels of strain under physiologic pressure compared to the other model, but the resulting strain values under pressure equalization were > 60% and did not correspond to experimental values. Since pressure equalization may increase the dynamic range of strain imaging, the effect of the surrounding tissue on strain should be incorporated into models of arterial strain, particularly when the pressure equalization technique is used.
DOI: 10.1093/ndt/15.7.1014
发表时间: 2000-07-01
影响因子: 6.1
作者:
Guérin, AP;London, GM;Metivier, F
通讯作者: Metivier, F
DOI: 10.1109/58.285465
发表时间: 1994-05-01
影响因子: 3.6
作者:
ODONNELL, M;SKOVORODA, AR;EMELIANOV, SY
通讯作者: EMELIANOV, SY
DOI: 10.1097/rli.0b013e31816085fc
发表时间: 2008-04-01
影响因子: 6.7
作者:
Pislaru, Cristina;Kantor, Birgit;Greenleaf, James F.
通讯作者: Greenleaf, James F.
DOI: 10.1109/58.741427
发表时间: 1999-01-01
影响因子: 3.6
作者:
Lubinski, MA;Emelianov, SY;O'Donnell, M
通讯作者: O'Donnell, M
DOI: 10.1093/ndt/12.12.2629
发表时间: 1997-12-01
影响因子: 6.1
作者:
Luik, AJ;Spek, JJ;Leunissen, KML
通讯作者: Leunissen, KML