Image Quality and Dose Comparison of 3 Mobile Intraoperative Three-Dimensional Imaging Systems in Spine Surgery.
Image Quality and Dose Comparison of 3 Mobile Intraoperative Three-Dimensional Imaging Systems in Spine Surgery.
复制标题
DOI:
10.1016/j.wneu.2021.12.103
复制
发表时间:
2022-04
影响因子:
2
通讯作者:
Goode, Allen
中科院分区:
文献类型:
--
作者:
Foster, Norah;Shaffrey, Christopher;Buchholz, Avery;Turner, Raymond;Yang, Lexie Zidanyue;Niedzwiecki, Donna;Goode, Allen
This study evaluated the radiation exposure and image quality for three intraoperative imaging systems (Airo, Spin, O-arm) using varying radiation dose settings in a single cadaver model. Axial images of L4–5 instrumentation were obtained using three manufacturer dose protocols for each system. Measurements included scattered radiation dose, subjective and objective image quality (IQ) and estimates of patient effective dose (ED). Four images per system were selected at each dose level. Using the Likert scale (1- best, 5- worst), nine reviewers rated the same 36 images. Objective IQ measures the degree of streak artifacts (lines with incorrect data from metal objects) in each image. A composite figure of merit (FOM) was derived based on ED and subjective and objective scores. The best subjective IQ scores were Spin medium (1.44), high dose (1.78), and Airo (2.22) low dose. The best objective IQ scores were Airo (87.3), followed by Spin (89.1). ED low dose results in mSv included Airo (1.6), Spin (1.9) and O-arm (3.3). The ED high-dose results in mSv included Spin (4.6), Airo (9.7) and O-arm (9.9). Scatter radiation measurements for low dose in μGy included Spin (21.9), Airo (31.8) and O-arm (33.9). Scatter radiation for high dose in μGy included Spin (55.9), O-arm (104.5) and Airo (200). The best FOM score was for the Airo low dose, followed by Spin medium and high dose. The selection of intraoperative imaging systems requires a greater understanding of the risks and benefits of radiation exposure and IQ.
登录
查看更多内容
DOI:
10.3233/thc-218021
发表时间:
2021
期刊:
Technology and health care : official journal of the European Society for Engineering and Medicine
影响因子:
--
作者:
Chiang HW;Wu RW;Yin TC;Li JH;Wang YS;Lin LH
通讯作者:
Lin LH
影响因子:
1.7
作者:
Smith, Harvey E.;Welsch, Matthew D.;Vaccaro, Alexander R.
通讯作者:
Vaccaro, Alexander R.
影响因子:
2.8
作者:
Godzik, Jakub;Mastorakos, George M.;Tumialan, Luis M.
通讯作者:
Tumialan, Luis M.
影响因子:
3
作者:
Prasarn, Mark L.;Coyne, Ellen;Rechtine, Glenn R.
通讯作者:
Rechtine, Glenn R.
影响因子:
2.7
作者:
Hwang YS;Tsai HY;Lin YY;Lui KW
通讯作者:
Lui KW