Spatial variations in Achilles tendon shear wave speed.
Spatial variations in Achilles tendon shear wave speed.
复制标题
DOI:
10.1016/j.jbiomech.2014.05.008
复制
发表时间:
2014-08-22
影响因子:
2.4
通讯作者:
Thelen, Darryl G.
中科院分区:
文献类型:
--
作者:
DeWall, Ryan J.;Slane, Laura C.;Lee, Kenneth S.;Thelen, Darryl G.
关键词:
Supersonic shear imaging (SSI) is an ultrasound imaging modality that can provide insight into tissue mechanics by measuring shear wave propagation speed, a property that depends on tissue elasticity. SSI has previously been used to characterize the increase in Achilles tendon shear wave speed that occurs with loading, an effect attributable to the strain-stiffening behavior of the tissue. However, little is known about how shear wave speed varies spatially, which is important, given the anatomical variation that occurs between the calcaneus insertion and the gastrocnemius musculotendon junction. The purpose of this study was to investigate spatial variations in shear wave speed along medial and lateral paths of the Achilles tendon for three different ankle postures: resting ankle angle (R, i.e. neutral), plantarflexed (P; R − 15 deg), and dorsiflexed (D; R + 15 deg). We observed significant spatial and posture variations in tendon shear wave speed in ten healthy young adults. Shear wave speeds in the Achilles free tendon averaged 12 ± 1.2 m/s in a resting position, but decreased to 7.2 ± 1.8 m/s with passive plantarflexion. Distal tendon shear wave speeds often reached the maximum tracking limit (16.3 m/s) of the system when the ankle was in the passively dorsiflexed posture (+15 deg from R). At a fixed posture, shear wave speeds decreased significantly from the free tendon to the gastrocnemius musculotendon junction, with slightly higher speeds measured on the medial side than on the lateral side. Shear wave speeds were only weakly correlated with the thickness and depth of the tendon, suggesting that the distal-to-proximal variations may reflect greater compliance in the aponeurosis relative to the free tendon. The results highlight the importance of considering both limb posture and transducer positioning when using SSI for biomechanical and clinical assessments of the Achilles tendon.
登录
查看更多内容
影响因子:
2.3
作者:
Chen, Xiang-Mei;Cui, Li-Gang;Wang, Jin-Rui
通讯作者:
Wang, Jin-Rui
影响因子:
19.7
作者:
Athanasiou, Alexandra;Tardivon, Anne;Neuenschwander, Sylvia
通讯作者:
Neuenschwander, Sylvia
影响因子:
4.8
作者:
JOZSA, L;KVIST, M;BARZO, M
通讯作者:
BARZO, M
影响因子:
2.4
作者:
Hawkins, David;Lum, Corey;Dunning, Russell
通讯作者:
Dunning, Russell
影响因子:
2.4
作者:
Antonios, Tony;Adds, Philip J.
通讯作者:
Adds, Philip J.