Histotripsy Ablations in a Porcine Liver Model: Feasibility of Respiratory Motion Compensation by Alteration of the Ablation Zone Prescription Shape.

Histotripsy Ablations in a Porcine Liver Model: Feasibility of Respiratory Motion Compensation by Alteration of the Ablation Zone Prescription Shape.
复制标题

DOI:
10.1007/s00270-020-02582-7
复制
发表时间:
2020-11
影响因子:
2.9
通讯作者:
Ziemlewicz TJ
Ziemlewicz TJ
中科院分区:
医学3区
文献类型:
--
作者:
Longo KC;Zlevor AM;Laeseke PF;Swietlik JF;Knott EA;Rodgers AC;Mao L;Zhang X;Xu Z;Wagner MG;Periyasamy S;Lee FT Jr;Ziemlewicz TJ

文献摘要

参考文献

相似文献

Previous human-scale porcine liver model studies of histotripsy have resulted in ablation zones elongated in the cranial-caudal (CC) dimension due to uninterrupted respiratory motion during the ablation procedure. The purpose of this study is to compensate for elongation of hepatic histotripsy ablation zones in the cranial-caudal (CC) dimension caused by respiratory motion by prescribing ellipsoid shaped ablations. Six female swine underwent 12 hepatic histotripsy ablations using a prototype clinical histotripsy system under general anesthesia. Each animal received two ablation zones prescribed as either an ellipsoid (2.5cm (AP) x 2.5cm (ML) x 1.7cm (CC), prescribed volume=5.8cc) or a sphere (2.5cm all dimensions, prescribed volume 8.2cc). Ventilatory tidal volume was held constant at 400cc for all ablations. Post procedure MRI was followed by sacrifice and gross and microscopic histology. Ablations on MRI were slightly larger than prescribed in all dimensions. Ellipsoid plan ablations (2.8 × 3.0 × 3.1cm, volume 13.2cc, sphericity index 0.987) were closer to prescribed volume than spherical plan ablations (2.9 × 3.1 × 3.7cm, volume 17.1cc, sphericity index 0.953). Ellipsoid plan ablations were more spherical than sphere plan ablations, but the difference did not reach statistical significance (p=.06). Pathologic analysis confirmed complete necrosis within the center of each ablation zone with no widening of the zone of partial ablation on the superior and inferior as compared to the lateral borders (p=.22). Altering ablation zone prescription shape when performing hepatic histotripsy ablations can partially mitigate respiratory motion effects to achieve the desired ablation shape and volume.
DOI: 10.1016/j.ijrobp.2014.05.007
发表时间: 2014-09-01
影响因子: 7
作者:
Xu, Qianyi;Hanna, George;LaCouture, Tamara
通讯作者: LaCouture, Tamara
DOI: 10.1148/radiol.2018171544
发表时间: 2018-05-01
期刊: RADIOLOGY
影响因子: 19.7
作者:
Smolock, Amanda R.;Cristescu, Mircea M.;Lee, Fred T., Jr.
通讯作者: Lee, Fred T., Jr.
DOI: 10.1016/j.ijrobp.2005.03.072
发表时间: 2005-07-15
影响因子: 7
作者:
Dawson, LA;Eccles, C;Brock, KK
通讯作者: Brock, KK
DOI: 10.1007/s00270-013-0620-4
发表时间: 2014-02-01
影响因子: 2.9
作者:
Denys, Alban;Lachenal, Yann;Bize, Pierre
通讯作者: Bize, Pierre
DOI: 10.1016/j.ultrasmedbio.2005.09.005
发表时间: 2006-01-01
影响因子: 2.9
作者:
Parsons, JE;Cain, CA;Fowlkes, JB
通讯作者: Fowlkes, JB