Relationship between chlorhexidine gluconate skin concentration and microbial density on the skin of critically ill patients bathed daily with chlorhexidine gluconate.
Relationship between chlorhexidine gluconate skin concentration and microbial density on the skin of critically ill patients bathed daily with chlorhexidine gluconate.
复制标题
DOI:
10.1086/667371
复制
发表时间:
2012-09
影响因子:
4.5
通讯作者:
Hayden MK
中科院分区:
文献类型:
--
作者:
Popovich KJ;Lyles R;Hayes R;Hota B;Trick W;Weinstein RA;Hayden MK
Previous work has shown that daily skin cleansing with chlorhexidine gluconate (CHG) is effective in preventing infection in the medical intensive care unit (MICU). A colorimetric, semi-quantitative indicator was used to measure CHG concentration on skin (neck, antecubital fossae, inguinal areas) of patients bathed daily with CHG during MICU stay and after discharge from MICU, when CHG bathing stopped. Skin sites were also cultured quantitatively. The relationship between CHG concentration and microbial density on skin was explored in a mixed effects model using gram-positive colony forming unit (CFU) counts. For 20 MICU patients studied (240 measurements), lowest CHG concentrations (0–18.75μg/mL) and highest gram-positive CFUs were on the neck (median 1.07log10CFU, p=0.014). CHG concentration increased post-bath and decreased over 24h(p<0.001). In parallel, median log10CFUs decreased pre- to post-bath (0.78 to 0) and then increased over 24h to baseline of 0.78 (p=0.001). A CHG concentration >18.75μg/mL was associated with decreased gram-positive CFU(p=0.004). In all but 2 instances, CHG was detected on patient skin during entire inter-bath (~24h) period (18/20(90%) patients). In 11 patients studied after MICU discharge (80 measurements), CHG skin concentrations fell below effective levels after 1–3 days. In MICU patients bathed daily with CHG, CHG concentration was inversely associated with microbial density on skin; residual antimicrobial activity on skin persisted up to 24h. Determination of CHG concentration on patients’ skin may be useful in monitoring adequacy of skin cleansing by healthcare workers.
登录
查看更多内容
影响因子:
--
作者:
Vernon, MO;Hayden, MK;Weinstein, RA
通讯作者:
Weinstein, RA
影响因子:
4.5
作者:
Eckmanns, Tim;Bessert, Jan;Rueden, Henning
通讯作者:
Rueden, Henning
DOI:
10.1016/j.jamcollsurg.2007.12.054
发表时间:
2008-08-01
影响因子:
5.2
作者:
Edmiston, Charles E., Jr.;Krepel, Candace J.;Towne, Jonathan B.
通讯作者:
Towne, Jonathan B.
影响因子:
5.7
作者:
Fridkin, SK;Gaynes, RP
通讯作者:
Gaynes, RP
影响因子:
8.8
作者:
Climo, Michael W.;Sepkowitz, Kent A.;Wong, Edward S.
通讯作者:
Wong, Edward S.