Portable two-color photometer based on paired light emitter detector diodes and its application to the determination of paraquat and diquat
Portable two-color photometer based on paired light emitter detector diodes and its application to the determination of paraquat and diquat
复制标题
基于成对光发射检测二极管的便携式双色光度计及其在百草枯和敌草快测定中的应用
DOI:
10.1016/j.microc.2021.106777
复制
发表时间:
2021
影响因子:
4.8
通讯作者:
Kaneta Takashi
中科院分区:
文献类型:
--
作者:
Seetasang Sasikarn;Kaneta Takashi
Here we describe a methodology for the determination of paraquat and diquat using a newly developed portable photometer equipped with two colors of paired light emitter detector diodes (PEDD). The colorimetric measurements employed in this work include the redox reactions between 1) dithiothreitol and diquat to produce the red color characteristic of a diquat radical and 2) between sodium dithionite and either diquat or paraquat that results in the green and blue colors of diquat and paraquat radicals, respectively. The addition of sodium dithionite or dithiothreitol in a solid-state provides reproducible absorbance of the radicals, prevents decomposition of the reagents in a solution, and simplifies handling of the reagents. The diquat radical produced by dithiothreitol (λmax= 495 nm) was successfully detected by using a pair of blue LEDs with a maximum emission wavelength at 472 nm while the radicals of paraquat (λmax= 603 nm) and diquat (λmax= 771 nm) reduced by sodium dithionite were measured by a pair of orange LEDs with a maximum emission wavelength of 609 nm. The proposed method consists of measuring diquat radicals at 472 nm, estimating the absorbance of diquat radicals at 609 nm, and subtracting the estimated absorbance of diquat radicals from the total absorbance at 609 nm to determine paraquat radicals. The developed method yielded examples of excellent linear regression (r2) of more than 0.99 in three calibration curves of the radicals measured at 472 nm for diquat radicals and measured at 609 nm for both diquat and paraquat radicals. The intra-day (n = 3) and inter-day (n = 3) precision of three calibration curves were less than or equal to 5%. By comparison with the standard method of high-performance liquid chromatography, the reliability of the proposed method was proven via the analysis of paraquat and diquat radicals in a commercially available herbicide.
登录
查看更多内容
影响因子:
2.2
作者:
K. Minakata;Osamu Suzuki;Minoru Asano
通讯作者:
Minoru Asano
影响因子:
2
作者:
FLASCHKA, H;MCKEITHAN, C;BARNES, R
通讯作者:
BARNES, R
影响因子:
2.2
作者:
T. Matsuoka;J. Okuda
通讯作者:
J. Okuda
DOI:
10.1016/j.microc.2016.07.009
发表时间:
2016
期刊:
影响因子:
--
作者:
Diogo S. Silva;B. Reis
通讯作者:
B. Reis
影响因子:
5.8
作者:
M. Rose;E. Lock;L. L. Smith;I. Wyatt
通讯作者:
I. Wyatt