Evaluation on Effectiveness of a New System as well as Analysis on Optimal Horizontal Eye Position for Vertical Video Head Impulse Test
Evaluation on Effectiveness of a New System as well as Analysis on Optimal Horizontal Eye Position for Vertical Video Head Impulse Test
复制标题
新系统的有效性评估以及垂直视频头脉冲测试的最佳水平眼位分析
DOI:
10.1007/s11596-021-2415-1
复制
发表时间:
2021-08
影响因子:
2.4
通讯作者:
Li Wen-yan
中科院分区:
文献类型:
--
作者:
Jiang Tao;Li Fei;Yu Jing;Huang Ruo-nan;Gao Rui;Shang Chen-yong;Zhuang Jian-hua;Li Wen-yan
ObjectiveTo compare the performances among three different systems for video head impulse test (vHIT), and to identify an optimal target angle for precisely evaluating the function of vertical semicircular canals in vHIT.MethodsA two-center prospective study was done. Participants were sit 1.2 m away from the wall in a noise-proved room that dedicated for vHIT experiments. During the comparison experiments, similar settings were ensured in both hospitals, with the same distance to wall and angle of staring. For each equipment, the procedures followed the developers’ recommendations. The same examiner performed the comparison between two systems in one location. For the eye-position projects, targets were placed on the wall sequentially at the pre-marked lines for different angles. For the comparison projects, 9 and 13 participants were recruited, respectively. Any participant with otologic or vestibular disorders was excluded. A total of 26 healthy participants were recruited in the eye-position experiments, 16 of which were further involved in inter-examiner tests.ResultsOur evaluations of three different systems showed that a new vHIT system, VertiGoggles® ZT-VNG-I (VG) performed as good as the long-tested Otometrics® ICS impulse (Oto) and EyeSeeCam® (ESC). During the comparison, we validated 25-degree, instead of right ahead at 0 degree, is a better place to set the targets when torsion was applied at vertical semicircular canal planes.ConclusionThe new VG system is good for clinical practices. Furthermore, we proposed a new protocol to set the targets 25 degrees from right ahead after tilting head 45 degrees to evaluate vertical canals during vHIT.
登录
查看更多内容
影响因子:
3.4
作者:
McGarvie LA;Martinez-Lopez M;Burgess AM;MacDougall HG;Curthoys IS
通讯作者:
Curthoys IS
DOI:
10.3233/ves-2011-0421
发表时间:
2011-01-01
影响因子:
2.3
作者:
Migliaccio, Americo A.;Cremer, Phillip D.
通讯作者:
Cremer, Phillip D.
DOI:
10.1177/0194599818779908
发表时间:
2018-10
期刊:
Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery
影响因子:
--
作者:
Judge PD;Rodriguez AI;Barin K;Janky KL
通讯作者:
Janky KL
影响因子:
9.9
作者:
MacDougall, H. G.;Weber, K. P.;Curthoys, I. S.
通讯作者:
Curthoys, I. S.
影响因子:
7.7
作者:
Jiang, Tao;Kindt, Katie;Wu, Doris K.
通讯作者:
Wu, Doris K.