Methods for using 3-D ultrasound speckle tracking in biaxial mechanical testing of biological tissue samples.

Methods for using 3-D ultrasound speckle tracking in biaxial mechanical testing of biological tissue samples.
复制标题

DOI:
10.1016/j.ultrasmedbio.2014.10.021
复制
发表时间:
2015-04
影响因子:
2.9
通讯作者:
Kim, Kang
Kim, Kang
中科院分区:
医学3区
文献类型:
--
作者:
Yap, Choon Hwai;Park, Dae Woo;Dutta, Debaditya;Simon, Marc;Kim, Kang

文献摘要

参考文献

被引文献

相似文献

Being multilayered and anisotropic, biological tissues such as cardiac and arterial walls are structurally complex, making full assessment and understanding of their mechanical behavior challenging. Current standard mechanical testing uses surface markers to track tissue deformations and does not provide deformation data below the surface. In the study described here, we found that combining mechanical testing with 3-D ultrasound speckle tracking could overcome this limitation. Rat myocardium was tested with a biaxial tester and was concurrently scanned with high-frequency ultrasound in three dimensions. The strain energy function was computed from stresses and strains using an iterative non-linear curve-fitting algorithm. Because the strain energy function consists of terms for the base matrix and for embedded fibers, spatially varying fiber orientation was also computed by curve fitting. Using finite-element simulations, we first validated the accuracy of the non-linear curve-fitting algorithm. Next, we compared experimentally measured rat myocardium strain energy function values with those in the literature and found a matching order of magnitude. Finally, we retained samples after the experiments for fiber orientation quantification using histology and found that the results satisfactorily matched those computed in the experiments. We conclude that 3-D ultrasound speckle tracking can be a useful addition to traditional mechanical testing of biological tissues and may provide the benefit of enabling fiber orientation computation.
DOI: 10.1007/s10439-009-9812-0
发表时间: 2010-02
影响因子: 3.8
作者:
Gao, Zhan;Lister, Kevin;Desai, Jaydev P.
通讯作者: Desai, Jaydev P.
DOI: 10.1109/58.285465
发表时间: 1994-05-01
影响因子: 3.6
作者:
ODONNELL, M;SKOVORODA, AR;EMELIANOV, SY
通讯作者: EMELIANOV, SY
DOI: 10.1016/s0021-9290(02)00444-x
发表时间: 2003-05-01
影响因子: 2.4
作者:
Rachev, A;Greenwald, SE
通讯作者: Greenwald, SE
DOI: 10.1152/ajpheart.2001.280.5.h2222
发表时间: 2001-05-01
影响因子: 4.8
作者:
Arts, T;Costa, KD;McCulloch, AD
通讯作者: McCulloch, AD
DOI: 10.1161/01.cir.100.4.361
发表时间: 1999-07-27
期刊: CIRCULATION
影响因子: 37.8
作者:
Stuber, M;Scheidegger, MB;Boesiger, P
通讯作者: Boesiger, P