The Use of Smartphone Photogrammetry to Digitise Transtibial Sockets: Optimisation of Method and Quantitative Evaluation of Suitability.
The Use of Smartphone Photogrammetry to Digitise Transtibial Sockets: Optimisation of Method and Quantitative Evaluation of Suitability.
复制标题
使用智能手机摄影测量数字化transobial插座:方法的优化和适用性的定量评估。
DOI:
10.3390/s21248405
复制
发表时间:
2021-12-16
期刊:
影响因子:
--
通讯作者:
Du X
中科院分区:
文献类型:
--
作者:
Cullen S;Mackay R;Mohagheghi A;Du X
The fit of a lower limb prosthetic socket is critical for user comfort and the quality of life of lower limb amputees. Sockets are conventionally produced using hand-crafted patient-based casting techniques. Modern digital techniques offer a host of advantages to the process and ultimately lead to improving the lives of amputees. However, commercially available scanning equipment required is often expensive and proprietary. Smartphone photogrammetry could offer a low cost alternative, but there is no widely accepted imaging technique for prosthetic socket digitisation. Therefore, this paper aims to determine an optimal imaging technique for whole socket photogrammetry and evaluate the resultant scan measurement accuracy. A 3D printed transtibial socket was produced to create digital and physical twins, as reference models. The printed socket was photographed from 360 positions and simplified genetic algorithms were used to design a series of experiments, whereby a collection of photos were processed using Autodesk ReCap. The most fit technique was used to assess accuracy. The accuracy of the socket wall volume, surface area and height were 61.63%, 99.61% and 99.90%, respectively, when compared to the digital reference model. The scanned model had a wall thickness ranging from 2.075 mm at the top to 7.758 mm towards the base of the socket, compared to a consistent thickness of 2.025 mm in the control model. The technique selected did not show sufficient accuracy for clinical application due to the degradation of accuracy nearer to the base of the socket interior. However, using an internal wall thickness estimation, scans may be of sufficient accuracy for clinical use; assuming a uniform wall thickness.
登录
查看更多内容
影响因子:
0.6
作者:
Dickinson, Alexander S.;Donovan-Hall, Maggie K.;Worsley, Peter R.
通讯作者:
Worsley, Peter R.
影响因子:
2.2
作者:
Grant, Caroline A.;Johnston, Melissa;Little, J. Paige
通讯作者:
Little, J. Paige
影响因子:
2.2
作者:
Sanders, Joan E.;Youngblood, Robert T.;Allyn, Katheryn J.
通讯作者:
Allyn, Katheryn J.
影响因子:
5.6
作者:
Ortiz-Sanz, J.;Gil-Docampo, M.;Tucci, G.
通讯作者:
Tucci, G.
影响因子:
4.6
作者:
Paternò L;Ibrahimi M;Rosini E;Menfi G;Monaco V;Gruppioni E;Ricotti L;Menciassi A
通讯作者:
Menciassi A