A gas monitoring chamber for high pressure applications
A gas monitoring chamber for high pressure applications
复制标题
适用于高压应用的气体监测室
DOI:
10.1088/1748-0221/16/08/p08030
复制
发表时间:
2020
影响因子:
1.3
通讯作者:
N. Thamm
中科院分区:
文献类型:
--
作者:
P. Hamacher;S. Roth;Thomas Radermacher;N. Thamm
Time Projection Chambers (TPCs) operated at high pressure have become a topic of interest for future long baseline neutrino experiments. Pressurized gas retains the low momentum threshold for particle detection of atmospheric TPCs, but offers a larger target mass for neutrino interactions at the same volume. Operation at high pressure poses several new challenges in safety aspects regarding overpressure and high voltage safety. The presented High Pressure Gas Monitoring Chamber (HPGMC) can be used to study the suitability of various drift gas mixtures up to 10 bar and a maximum field of ∼ 3000 V/cm. A flexible construction makes it possible to exchange parts of the inner detector and to test new technologies. In this work, the construction of a HPGMC and its commissioning using the P10 gas mixture (90 % Ar + 10 % CH4) are presented.