Acceptability of a home-based visual field test (Eyecatcher) for glaucoma home monitoring: a qualitative study of patients' views and experiences.

Acceptability of a home-based visual field test (Eyecatcher) for glaucoma home monitoring: a qualitative study of patients' views and experiences.
复制标题

DOI:
10.1136/bmjopen-2020-043130
复制
发表时间:
2021-04-05
期刊:
影响因子:
2.9
通讯作者:
Crabb DP
Crabb DP
中科院分区:
医学3区
文献类型:
--
作者:
Jones L;Callaghan T;Campbell P;Jones PR;Taylor DJ;Asfaw DS;Edgar DF;Crabb DP

文献摘要

参考文献

被引文献

相似文献

目的:探讨Eyecatcher家庭视野(VF)检测在参加为期6个月的家庭监测试点研究的青光眼患者中的可接受性。定性研究采用面对面的半结构访谈。使用主题分析对成绩单进行分析。参与者是通过国际青光眼协会(现为英国青光眼协会)时事通讯上的广告在英国招募的。2 0例确诊为青光眼(包括开角型青光眼和正常眼压型青光眼;平均偏差=2.5 ~−2 9.9 分贝)的患者中,女性10例,中位年龄71岁。所有参与者都可以在家中成功地进行VF测试。访谈数据被编码为四个主要主题,涉及进行VF家庭监测的经验和对其在医疗保健中更广泛实施的态度:(1)Eyecatcher和Humphrey field Analyser(HFA)之间的比较;(2)使用Eyecatcher的能力;(3)有效更广泛实施的实用性;(4)家庭监测的动机。与会者确定了VF家庭监控的广泛好处,并讨论了服务改进的领域。目测仪与传统的使用HFA的VF测试进行了积极的比较。至少一部分青光眼患者可以接受家庭监护。
To explore the acceptability of home visual field (VF) testing using Eyecatcher among people with glaucoma participating in a 6-month home monitoring pilot study. Qualitative study using face-to-face semistructured interviews. Transcripts were analysed using thematic analysis. Participants were recruited in the UK through an advertisement in the International Glaucoma Association (now Glaucoma UK) newsletter. Twenty adults (10 women; median age: 71 years) with a diagnosis of glaucoma were recruited (including open angle and normal tension glaucoma; mean deviation=2.5 to −29.9 dB). All participants could successfully perform VF testing at home. Interview data were coded into four overarching themes regarding experiences of undertaking VF home monitoring and attitudes towards its wider implementation in healthcare: (1) comparisons between Eyecatcher and Humphrey Field Analyser (HFA); (2) capability using Eyecatcher; (3) practicalities for effective wider scale implementation; (4) motivations for home monitoring. Participants identified a broad range of benefits to VF home monitoring and discussed areas for service improvement. Eyecatcher was compared positively with conventional VF testing using HFA. Home monitoring may be acceptable to at least a subset of people with glaucoma.
DOI: 10.3928/00989134-20121204-04
发表时间: 2013-01-01
影响因子: 1.3
作者:
Heinz, Melinda;Martin, Peter;Chang, Carl K.
通讯作者: Chang, Carl K.
DOI: 10.1016/s0140-6736(14)61461-6
发表时间: 2015-02-14
期刊: Lancet (London, England)
影响因子: --
作者:
Beard JR;Bloom DE
通讯作者: Bloom DE
DOI: 10.1136/bjo.86.5.560
发表时间: 2002-05-01
影响因子: 4.1
作者:
Gardiner, SK;Crabb, DP
通讯作者: Crabb, DP
DOI: 10.1167/tvst.5.6.2
发表时间: 2016-11-01
影响因子: 3
作者:
Kong, Yu Xiang George;He, Mingguang;Vingrys, Algis J.
通讯作者: Vingrys, Algis J.
DOI: 10.1136/bmjopen-2013-003996
发表时间: 2014-01-01
期刊: BMJ OPEN
影响因子: 2.9
作者:
Glen, Fiona C.;Baker, Helen;Crabb, David P.
通讯作者: Crabb, David P.