Hotspot temperature calculation and quench analysis on ITER busbar
Hotspot temperature calculation and quench analysis on ITER busbar
复制标题
ITER母线热点温度计算及失超分析
DOI:
10.1016/j.fusengdes.2014.08.013
复制
发表时间:
2014-12
影响因子:
1.7
通讯作者:
S.T. Wu
中科院分区:
文献类型:
--
作者:
J. Rong;X.Y. Huang;Y.T. Song;S.T. Wu
This paper describes the analysis of ITER feeder busbar, the hotspot temperature of busbar is calculated by classical method in the case of 0%, 50%, 75% and 100% extra copper (copper strands). The quench behavior of busbar is simulated by 1-D Gandalf code, and the MQE (minimum quench energy) is estimated in classical method as initial external heat in Gandalf input file. The temperature and the normal length of conductor are analyzed in the case of 0%, 50% and 100% extra copper and no helium. By hotspot temperature, conductor temperature and normal length are contrasted in different extra copper cases, it is shown that the extra copper play an important role in quench protecting.