Optimization of dual-saturation single bolus acquisition for quantitative cardiac perfusion and myocardial blood flow maps.
Optimization of dual-saturation single bolus acquisition for quantitative cardiac perfusion and myocardial blood flow maps.
复制标题
DOI:
10.1186/s12968-015-0116-2
复制
发表时间:
2015-02-19
期刊:
影响因子:
--
通讯作者:
Ibañez B
中科院分区:
文献类型:
--
作者:
Sánchez-González J;Fernandez-Jiménez R;Nothnagel ND;López-Martín G;Fuster V;Ibañez B
In-vivo quantification of cardiac perfusion is of great research and clinical value. The dual-bolus strategy is universally used in clinical protocols but has known limitations. The dual-saturation acquisition strategy has been proposed as a more accurate alternative, but has not been validated across the wide range of perfusion rates encountered clinically. Dual-saturation acquisition also lacks a clinically-applicable procedure for optimizing parameter selection. Here we present a comprehensive validation study of dual-saturation strategy in vitro and in vivo. The impact of saturation time and profile ordering in acquisitions was systematically analyzed in a phantom consisting of 15 tubes containing different concentrations of contrast agent. In-vivo experiments in healthy pigs were conducted to evaluate the effect of R2* on the definition of the arterial input function (AIF) and to evaluate the relationship between R2* and R1 variations during first-pass of the contrast agent. Quantification by dual-saturation perfusion was compared with the reference-standard dual-bolus strategy in 11 pigs with different grades of myocardial perfusion. Adequate flow estimation by the dual-saturation strategy is achieved with myocardial tissue saturation times around 100 ms (always <30 ms of AIF), with the lowest echo time, and following a signal model for contrast conversion that takes into account the residual R2* effect and profile ordering. There was a good correlation and agreement between myocardial perfusion quantitation by dual-saturation and dual-bolus techniques (R2 = 0.92, mean difference of 0.1 ml/min/g; myocardial perfusion ranges between 0.18 and 3.93 ml/min/g). The dual-saturation acquisition strategy produces accurate estimates of absolute myocardial perfusion in vivo. The procedure presented here can be applied with minimal interference in standard clinical procedures.
登录
查看更多内容
影响因子:
14
作者:
Hsu, Li-Yueh;Groves, Daniel W.;Aletras, Anthony H.;Kellman, Peter;Arai, Andrew E.
通讯作者:
Arai, Andrew E.
影响因子:
4.4
作者:
Hsu, LY;Rhoads, KL;Arai, AE
通讯作者:
Arai, AE
影响因子:
3.3
作者:
Kraitchman, DL;Wilke, N;Axel, L
通讯作者:
Axel, L
影响因子:
14
作者:
Chow, Benjamin J. W.;Dorbala, Sharmila;Beanlands, Rob S.
通讯作者:
Beanlands, Rob S.
影响因子:
3.3
作者:
WILKE, N;SIMM, C;UGURBIL, K
通讯作者:
UGURBIL, K