Whole-brain vessel wall MRI: A parameter tune-up solution to improve the scan efficiency of three-dimensional variable flip-angle turbo spin-echo.
Whole-brain vessel wall MRI: A parameter tune-up solution to improve the scan efficiency of three-dimensional variable flip-angle turbo spin-echo.
复制标题
DOI:
10.1002/jmri.25611
复制
发表时间:
2017-09
期刊:
影响因子:
--
通讯作者:
Fan Z
中科院分区:
文献类型:
--
作者:
Yang Q;Deng Z;Bi X;Song SS;Schlick KH;Gonzalez NR;Li D;Fan Z
To propose and evaluate a parameter tune-up solution to expedite a three-dimensional (3D) variable-flip-angle turbo spin-echo (TSE) sequence for whole-brain intracranial vessel wall (IVW) imaging. Elliptical k-space sampling and prolonged echo train length (ETL), were used to expedite a 3D variable-flip-angle TSE-based sequence. To compensate for the potential loss in vessel wall signal, optimal combination of prescribed T2 and ETL was experimentally investigated on 22 healthy volunteers at 3T. The optimized protocol (7–8 minutes) was then compared with a previous protocol (reference protocol, 11–12 minutes) in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and wall delineation quality on a 4-point scale (0:poor; 3:excellent) in 10 healthy volunteers. A pilot study of 5 patients was performed and lesion delineation score was used to demonstrate the diagnostic quality. A protocol with ETL=52 and prescribed T2=170ms was deemed an optimized one, which, compared to the reference protocol, provided significantly improved wall SNR (12.0±1.3 vs. 10.0±1.1, p=0.002), wall-lumen CNR (9.7±1.2 vs. 8.0±0.9, p=0.002), wall-CSF CNR (2.8±1.0 vs. 1.7±1.0, p=0.026), similar vessel wall sharpness at both inner (1.59±0.18 vs 1.58±0.14, p=0.87) and outer (1.71±0.25 vs. 1.83±0.30, p=0.18) boundaries, and comparable vessel wall delineation score for individual segments (1.95–3, p>0.06). In all patients, atherosclerotic plaques (10) or wall dissection (5) were identified with a delineation score of 3 or 2. A parameter tune-up solution can accelerate 3D variable-flip-angle TSE acquisitions, particularly allowed for expedited whole-brain IVW imaging with preserved wall delineation quality.
登录
查看更多内容
影响因子:
3.3
作者:
Busse, Reed F.;Brau, Anja C. S.;Vu, Anthony;Michelich, Charles R.;Bayram, Ersin;Kijowski, Richard;Reeder, Scott B.;Rowley, Howard A.
通讯作者:
Rowley, Howard A.
影响因子:
3.3
作者:
Viessmann O;Li L;Benjamin P;Jezzard P
通讯作者:
Jezzard P
DOI:
10.1136/jnnp-2015-312020
发表时间:
2016-06
期刊:
Journal of neurology, neurosurgery, and psychiatry
影响因子:
--
作者:
Alexander MD;Yuan C;Rutman A;Tirschwell DL;Palagallo G;Gandhi D;Sekhar LN;Mossa-Basha M
通讯作者:
Mossa-Basha M
影响因子:
3.5
作者:
Sakurai, Keita;Miura, Toshiyasu;Shibamoto, Yuta
通讯作者:
Shibamoto, Yuta
影响因子:
19.7
作者:
Li, DB;Carr, JC;Finn, JP
通讯作者:
Finn, JP