eBP: A Wearable System For Frequent and Comfortable Blood Pressure Monitoring From User's Ear
eBP: A Wearable System For Frequent and Comfortable Blood Pressure Monitoring From User's Ear
复制标题
eBP:一种可穿戴系统,可通过用户的耳朵进行频繁、舒适的血压监测
DOI:
10.1145/3300061.3345454
复制
发表时间:
2019
期刊:
影响因子:
--
通讯作者:
Xiao, Jianliang
中科院分区:
文献类型:
--
作者:
Bui, Nam;Pham, Nhat;Barnitz, Jessica Jacqueline;Zou, Zhanan;Nguyen, Phuc;Truong, Hoang;Kim, Taeho;Farrow, Nicholas;Nguyen, Anh;Xiao, Jianliang
Frequent blood pressure (BP) assessment is key to the diagnosis and treatment of many severe diseases, such as heart failure, kidney failure, hypertension, and hemodialysis. Current "gold-standard'' BP measurement techniques require the complete blockage of blood flow, which causes discomfort and disruption to normal activity when the assessment is done repetitively and frequently. Unfortunately, patients with hypertension or hemodialysis often have to get their BP measured every 15 minutes for a duration of 4-5 hours or more. The discomfort of wearing a cumbersome and limited mobility device affects their normal activities. In this work, we propose a device called eBP to measure BP from inside the user's ear aiming to minimize the measurement's impact on users' normal activities while maximizing its comfort level. eBP has 3 key components: (1) a light-based pulse sensor attached on an inflatable pipe that goes inside the ear, (2) a digital air pump with a fine controller, and (3) a BP estimation algorithm. In contrast to existing devices, eBP introduces a novel technique that eliminates the need to block the blood flow inside the ear, which alleviates the user's discomfort. We prototyped eBP custom hardware and software and evaluated the system through a comparative study on 35 subjects. The study shows that eBP obtains the average error of 1.8 mmHg and -3.1 mmHg and a standard deviation error of 7.2 mmHg and 7.9 mmHg for systolic (high-pressure value) and diastolic (low-pressure value), respectively. These errors are around the acceptable margins regulated by the FDA's AAMI protocol, which allows mean errors of up to 5 mmHg and a standard deviation of up to 8 mmHg.
登录
查看更多内容
影响因子:
3.2
作者:
A. Adji
通讯作者:
A. Adji
DOI:
10.1023/a:1016903508976
发表时间:
1996
期刊:
International Journal of Clinical Monitoring and Computing
影响因子:
--
作者:
M. Todorović;E. Jensen;C. Thøgersen
通讯作者:
C. Thøgersen
DOI:
10.1109/embc.2012.6346655
发表时间:
2012
期刊:
2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society
影响因子:
--
作者:
M. Mafi;S. Rajan;M. Bolic;V. Groza;H. Dajani
通讯作者:
H. Dajani
影响因子:
4.6
作者:
Liu, Jing;Yan, Bryan P.;Zhao, Ni
通讯作者:
Zhao, Ni
影响因子:
5.7
作者:
E. O’Brien
通讯作者:
E. O’Brien