Enabling Biocatalysis by High-Throughput Protein Engineering Using Droplet Microfluidics Coupled to Mass Spectrometry.
Enabling Biocatalysis by High-Throughput Protein Engineering Using Droplet Microfluidics Coupled to Mass Spectrometry.
复制标题
DOI:
10.1021/acsomega.7b01973
复制
发表时间:
2018-02-28
期刊:
影响因子:
4.1
通讯作者:
Moore JC
中科院分区:
文献类型:
--
作者:
Diefenbach XW;Farasat I;Guetschow ED;Welch CJ;Kennedy RT;Sun S;Moore JC
Directed Evolution is a key technology driving the utility of biocatalysis in pharmaceutical synthesis. Conventional approaches to Directed Evolution are conducted using bacterial cells expressing enzymes in microplates, with catalyzed reactions measured by HPLC, high-performance liquid chromatography-mass spectrometry (HPLC-MS), or optical detectors, which require either long cycle times or tailor-made substrates. To better fit modern, fast-paced process chemistry development where solutions are rapidly needed for new substrates, droplet microfluidics interfaced with electrospray ionization (ESI)-MS provides a label-free high-throughput screening platform. To apply this method to industrial enzyme screening and to explore potential approaches that may further improve the overall throughput, we optimized the existing droplet–MS methods. Carryover between droplets, traditionally a significant issue, was reduced to undetectable level by replacing the stainless steel ESI needle with a Teflon needle within a capillary electrophoresis (CE)–MS source. Throughput was improved to 3 Hz with a wide range of droplet sizes (10–50 nL) by tuning the sheath flow within the CE–MS source. The optimized method was demonstrated by screening reactions using two different transaminase libraries. Good correlations (r2 ∼ 0.95) were found between the droplet–MS and LC–MS methods, with 100% match on hit variants. We further explored the capability of the system by performing in vitro transcription–translation inside the droplets and directly analyzing the intact reaction mixture droplets by MS. The synthesized protein attained comparable activity to the protein standard, and the complex samples appeared well tolerated by the MS. The success of the above applications indicates that the MS analysis of the microfluidic droplets is an available option for considerably accelerating the screening of enzyme evolution libraries.
登录
查看更多内容
DOI:
10.1177/2472555217717473
发表时间:
2017-12
期刊:
SLAS discovery : advancing life sciences R & D
影响因子:
--
作者:
Heap RE;Hope AG;Pearson LA;Reyskens KMSE;McElroy SP;Hastie CJ;Porter DW;Arthur JSC;Gray DW;Trost M
通讯作者:
Trost M
影响因子:
7.4
作者:
Sun, Shuwen;Slaney, Thomas R.;Kennedy, Robert T.
通讯作者:
Kennedy, Robert T.
影响因子:
16.6
作者:
Sun, Huihua;Yeo, Wan Lin;Ang, Ee Lui
通讯作者:
Ang, Ee Lui
影响因子:
15
作者:
Si T;Li B;Comi TJ;Wu Y;Hu P;Wu Y;Min Y;Mitchell DA;Zhao H;Sweedler JV
通讯作者:
Sweedler JV
影响因子:
6.4
作者:
Hibbert, EG;Dalby, PA
通讯作者:
Dalby, PA