99mTc-3P4-RGD2 scintimammography in the assessment of breast lesions: comparative study with 99mTc-MIBI.

99mTc-3P4-RGD2 scintimammography in the assessment of breast lesions: comparative study with 99mTc-MIBI.
复制标题

Tc-99m-3P(4)-RGD(2) 闪烁乳房X线照相术评估乳腺病变:与Tc-99m-MIBI的比较研究

DOI:
10.1371/journal.pone.0108349
复制
发表时间:
2014
期刊:
影响因子:
3.7
通讯作者:
Liu L
Liu L
中科院分区:
综合性期刊3区
文献类型:
--
作者:
Ma Q;Chen B;Gao S;Ji T;Wen Q;Song Y;Zhu L;Xu Z;Liu L

文献摘要

参考文献

被引文献

相似文献

To compare the potential application of 99mTc-3P-Arg-Gly-Asp (99mTc-3P4-RGD2) scintimammography (SMM) and 99mTc-methoxyisobutylisonitrile (99mTc-MIBI) SMM for the differentiation of malignant from benign breast lesions. Thirty-six patients with breast masses on physical examination and/or suspicious mammography results that required fine needle aspiration cytology biopsy (FNAB) were included in the study. 99mTc-3P4-RGD2 and 99mTc-MIBI SMM were performed with single photon emission computed tomography (SPECT) at 60 min and 20 min respectively after intravenous injection of 738±86 MBq radiotracers on a separate day. Images were evaluated by the tumor to non-tumor localization ratios (T/NT). Receiver operating characteristic (ROC) curve analysis was performed on each radiotracer to calculate the cut-off values of quantitative indices and to compare the diagnostic performance for the ability to differentiate malignant from benign diseases. The mean T/NT ratio of 99mTc-3P4-RGD2 in malignant lesions was significantly higher than that in benign lesions (3.54±1.51 vs. 1.83±0.98, p<0.001). The sensitivity, specificity, and accuracy of 99mTc-3P4-RGD2 SMM were 89.3%, 90.9% and 89.7%, respectively, with a T/NT cut-off value of 2.40. The mean T/NT ratio of 99mTc-MIBI in malignant lesions was also significantly higher than that in benign lesions (2.86±0.99 vs. 1.51±0.61, p<0.001). The sensitivity, specificity and accuracy of 99mTc-MIBI SMM were 87.5%, 72.7% and 82.1%, respectively, with a T/NT cut-off value of 1.45. According to the ROC analysis, the area under the curve for 99mTc-3P4-RGD2 SMM (area = 0.851) was higher than that for 99mTc-MIBI SMM (area = 0.781), but the statistical difference was not significant. 99mTc-3P4-RGD2 SMM does not provide any significant advantage over the established 99mTc-MIBI SMM for the detection of primary breast cancer. The T/NT ratio of 99mTc-3P4-RGD2 SMM was significantly higher than that of 99mTc-MIBI SMM. Both tracers could offer an alternative method for elucidating non-diagnostic mammograms.
DOI: 10.2967/jnumed.107.049452
发表时间: 2008-06-01
影响因子: 9.3
作者:
Kenny, Laura M.;Coombes, R. Charles;Aboagye, Eric O.
通讯作者: Aboagye, Eric O.
DOI: 10.1007/s11307-010-0385-y
发表时间: 2011-08-01
影响因子: 3.1
作者:
Jia, Bing;Liu, Zhaofei;Wang, Fan
通讯作者: Wang, Fan
DOI: 10.1093/jnci/86.8.614
发表时间: 1994-04-20
期刊: JOURNAL OF THE NATIONAL CANCER INSTITUTE
影响因子: --
作者:
GUIDI, AJ;FISCHER, L;SCHNITT, SJ
通讯作者: SCHNITT, SJ
DOI: 10.1148/radiology.196.2.7617855
发表时间: 1995-08-01
期刊: RADIOLOGY
影响因子: 19.7
作者:
KHALKHALI, I;CUTRONE, JA;KLEIN, SR
通讯作者: KLEIN, SR
DOI: 10.1371/journal.pone.0022418
发表时间: 2011
期刊: PloS one
影响因子: 3.7
作者:
Bhojani MS;Ranga R;Luker GD;Rehemtulla A;Ross BD;Van Dort ME
通讯作者: Van Dort ME