Toward Isolation of Palytoxins: Liquid Chromatography Coupled to Low- or High-Resolution Mass Spectrometry for the Study on the Impact of Drying Techniques, Solvents and Materials.
Toward Isolation of Palytoxins: Liquid Chromatography Coupled to Low- or High-Resolution Mass Spectrometry for the Study on the Impact of Drying Techniques, Solvents and Materials.
复制标题
分离沙冬青毒素:液相色谱-低分辨率或高分辨率质谱联用技术,用于研究干燥技术、溶剂和材料的影响。
DOI:
10.3390/toxins13090650
复制
发表时间:
2021-09-14
期刊:
影响因子:
4.2
通讯作者:
Dell'Aversano C
中科院分区:
文献类型:
--
作者:
Mazzeo A;Varra M;Tartaglione L;Ciminiello P;Zendong Z;Hess P;Dell'Aversano C
Palytoxin (PLTX) and its congeners are emerging toxins held responsible for a number of human poisonings following the inhalation of toxic aerosols, skin contact, or the ingestion of contaminated seafood. Despite the strong structural analogies, the relative toxic potencies of PLTX congeners are quite different, making it necessary to isolate them individually in sufficient amounts for toxicological and analytical purposes. Previous studies showed poor PLTX recoveries with a dramatic decrease in PLTX yield throughout each purification step. In view of a large-scale preparative work aimed at the preparation of PLTX reference material, we have investigated evaporation as a critical—although unavoidable—step that heavily affects overall recoveries. The experiments were carried out in two laboratories using different liquid chromatography-mass spectrometry (LC-MS) instruments, with either unit or high resolution. Palytoxin behaved differently when concentrated to a minimum volume rather than when evaporated to complete dryness. The recoveries strongly depended on the solubility as well as on the material of the used container. The LC-MS analyses of PLTX dissolved in aqueous organic blends proved to give a peak intensity higher then when dissolved in pure water. After drying, the PLTX adsorption appeared stronger on glass surfaces than on plastic materials. However, both the solvents used to dilute PLTX and that used for re-dissolution had an important role. A quantitative recovery (97%) was achieved when completely drying 80% aqueous EtOH solutions of PLTX under N2-stream in Teflon. The stability of PLTX in acids was also investigated. Although PLTX was quite stable in 0.2% acetic acid solutions, upon exposure to stronger acids (pH < 2.66), degradation products were observed, among which a PLTX methyl-ester was identified.
登录
查看更多内容
影响因子:
5.4
作者:
Kerbrat AS;Amzil Z;Pawlowiez R;Golubic S;Sibat M;Darius HT;Chinain M;Laurent D
通讯作者:
Laurent D
影响因子:
4.7
作者:
Movafaghi S;Wu H;Francino Urdániz IM;Bull DS;Kelly MD;Randolph TW;Goodwin AP
通讯作者:
Goodwin AP
影响因子:
5.4
作者:
Brissard C;Herrenknecht C;Séchet V;Hervé F;Pisapia F;Harcouet J;Lémée R;Chomérat N;Hess P;Amzil Z
通讯作者:
Amzil Z
影响因子:
17.3
作者:
Roberts, Christopher J.
通讯作者:
Roberts, Christopher J.
影响因子:
4.3
作者:
Ciminiello, Patrizia;Dell'Aversano, Carmela;Serpe, Luigi
通讯作者:
Serpe, Luigi