Performance of bioelectrical impedance analysis compared to dual X-ray absorptiometry (DXA) in Veterans with COPD.

Performance of bioelectrical impedance analysis compared to dual X-ray absorptiometry (DXA) in Veterans with COPD.
复制标题

DOI:
10.1038/s41598-022-05887-4
复制
发表时间:
2022-02-04
期刊:
影响因子:
4.6
通讯作者:
Wan ES
Wan ES
中科院分区:
综合性期刊3区
文献类型:
--
作者:
Cruz Rivera PN;Goldstein RL;Polak M;Lazzari AA;Moy ML;Wan ES

文献摘要

参考文献

被引文献

相似文献

我们检查了市售手持式生物阻抗 (BIA) 设备相对于双 X 射线吸收测定法 (DXA) 的性能,以评估患有慢性阻塞性肺病 (COPD) 的退伍军人的身体成分差异。使用 DXA 和 BIA (Omron HBF-306C) 在单个时间点测量身体成分。使用 Spearman (ρ) 和 Lin 相关系数 (ρc) 分析 BIA 和 DXA 评估的脂肪百分比、脂肪质量和去脂质量之间的相关性。使用 Bland-Altman 图可视化脂肪量的平均差异。按肥胖状况(BMI < 30 与 ≥ 30)进行亚组分析。在 50 名参与者(96% 男性;平均年龄:69.5±±6.0 岁)中,BIA 评估的脂肪量与 DXA 强相关(ρ = 0.94),并表现出极好的一致性(ρc = 0.95,[95%CI:0.93–0.98]),平均差异为BIA 和 DXA 之间为 2.7 ± 3.2 kg。尽管 BIA 和 DXA 评估的脂肪百分比和去脂质量之间的斯皮尔曼相关性很强(分别为 ρ = 0.8 和 0.91),但一致性值仅为中等(分别为 ρ = 0.67 和 0.74)。相对于非肥胖受试者,肥胖受试者在总脂肪百分比(ρobese = 0.85 与 ρnon-obese = 0.5)和脂肪量(ρobese = 0.96 与 ρnon-obese = 0.84)方面观察到显着更强的相关性。手持式 BIA 设备在脂肪量方面与 DXA 表现出高度一致性,在总脂肪百分比和无脂肪质量方面表现出中等一致性。 ClinicalTrials.gov:NCT02099799。
We examined the performance of a commercially-available handheld bioimpedance (BIA) device relative to dual X-ray absorptiometry (DXA) to assess body composition differences among Veterans with chronic obstructive pulmonary disease (COPD). Body composition was measured using DXA and BIA (Omron HBF-306C) at a single time point. Correlations between BIA- and DXA-assessed percent fat, fat mass, and fat-free mass were analyzed using Spearman (ρ) and Lin Concordance Correlation Coefficients (ρc). Mean differences in fat mass were visualized using Bland–Altman plots. Subgroup analyses by obesity status (BMI < 30 versus ≥ 30) were performed. Among 50 participants (96% male; mean age: 69.5 ± 6.0 years), BIA-assessed fat mass was strongly correlated (ρ = 0.94) and demonstrate excellent concordance (ρc = 0.95, [95%CI: 0.93–0.98]) with DXA, with a mean difference of 2.7 ± 3.2 kg between BIA and DXA. Although Spearman correlations between BIA- and DXA-assessed percent fat and fat-free mass were strong (ρ = 0.8 and 0.91, respectively), concordance values were only moderate (ρc = 0.67 and 0.74, respectively). Significantly stronger correlations were observed for obese relative to non-obese subjects for total percent fat (ρobese = 0.85 versus ρnon-obese = 0.5) and fat mass (ρobese = 0.96 versus ρnon-obese = 0.84). A handheld BIA device demonstrated high concordance with DXA for fat mass and moderate concordance for total percent fat and fat-free mass. ClinicalTrials.gov: NCT02099799.
DOI: 10.1038/oby.2006.32
发表时间: 2006-02-01
期刊: OBESITY
影响因子: 6.9
作者:
Rush, Elaine C.;Crowley, Jennifer;Luke, Amy
通讯作者: Luke, Amy
DOI: 10.1183/23120541.00158-2021
发表时间: 2021-07-01
期刊: ERJ OPEN RESEARCH
影响因子: 4.6
作者:
Robinson, Stephanie A.;Cooper, J. Allen, Jr.;Moy, Marilyn L.
通讯作者: Moy, Marilyn L.
DOI: 10.1079/bjn20061798
发表时间: 2006-07-01
影响因子: 3.6
作者:
Lerario, M. C.;Sachs, A.;Jardim, J. R.
通讯作者: Jardim, J. R.
DOI: 10.1016/j.hrtlng.2012.02.010
发表时间: 2012-07-01
期刊: HEART & LUNG
影响因子: 2.8
作者:
Lan, Chou-Chin;Su, Chiu-Ping;Wu, Yao-Kuang
通讯作者: Wu, Yao-Kuang
DOI: 10.1016/j.chest.2019.01.001
发表时间: 2019-06-01
期刊: CHEST
影响因子: 9.6
作者:
de Blasio, Francesca;Scalfi, Luca;de Blasio, Francesco
通讯作者: de Blasio, Francesco