目前,世界各地正在研究开发用于商业化的超导电力电缆。已经进行了许多连接到真实的电网的超导电力电缆的示范,根据配电和输电线路的电压水平进行了各种设计。在韩国,由韩国电力公司(KEPCO)全额资助的第一个高温超导(HTS)电力电缆商业项目“Shingal项目”正在进行中,该项目将用23 kV HTS电缆连接两个变电站,距离为1公里。此外,KEPCO研究中心(KEPRI)于2017年启动了该项目,以开发23 kV三轴高温超导电力电缆,包括冷却系统,距离为3公里。本文介绍了两个23 kV超导电力电缆项目的最新进展和研究活动。考虑到高温超导电力电缆的建设环境和社会问题,对高温超导电力电缆的商业化进行了经济评价。
Research on the development of a superconducting power cable for commercialization is currently underway across the world. Many demonstrations of superconducting power cables connected to real power grids have already been conducted with various designs depending on the voltage levels of the distribution and transmission lines. In Korea, the first commercial project for high temperature superconducting (HTS) power cables, “Shingal Project” which is fully funded by Korea Electric Power Corporation (KEPCO), is underway to connect two substations with a 23 kV HTS cable with a distance of 1 km. In addition, the KEPCO Research Center (KEPRI) initiated the project in 2017 to develop the 23-kV tri-axial HTS power cables, including a cooling system, for a distance of 3 km. In this paper, the recent progress and research activities related to the two 23-kV superconducting power cables projects are discussed. An economic evaluation of the HTS power cables for commercialization in consideration of their construction environments and social issues is also presented.
韩国交直流输电高温超导电缆的现状及进展
DOI: --
发表时间: 2018
影响因子: 1.8
作者:
Seok;Minwon Park;I. Yu;Y. Won;Yangho Kwak;Chulhyu Lee
通讯作者: Chulhyu Lee
DOI: 10.1049/cp.2013.0945
发表时间: 2013
期刊: --
影响因子: --
作者:
M. Elsherif;P. Taylor;S. Blake
通讯作者: S. Blake
AmpaCity 项目 先进的超导 10 kV 系统取代市中心传统的 110 kV 电缆系统
DOI: --
发表时间: 2013
期刊: --
影响因子: --
作者:
M. Stemmle;F. Merschel;M. Noe;A. Hobl
通讯作者: A. Hobl
DOI: 10.1109/tasc.2010.2092744
发表时间: 2011
影响因子: 1.8
作者:
S. Honjo;T. Mimura;Y. Kitoh;Y. Noguchi;T. Masuda;H. Yumura;M. Watanabe;M. Ikeuchi;H. Yaguchi;T. Hara
通讯作者: T. Hara