Cochlear-implant spatial selectivity with monopolar, bipolar and tripolar stimulation.

Cochlear-implant spatial selectivity with monopolar, bipolar and tripolar stimulation.
复制标题

DOI:
10.1016/j.heares.2011.11.005
复制
发表时间:
2012-01
期刊:
影响因子:
2.8
通讯作者:
Ye, Datian
Ye, Datian
中科院分区:
医学1区
文献类型:
--
作者:
Zhu, Ziyan;Tang, Qing;Zeng, Fan-Gang;Guan, Tian;Ye, Datian

文献摘要

参考文献

相似文献

Sharp spatial selectivity is critical to auditory performance, particularly in pitch related tasks. Most contemporary cochlear implants have employed monopolar stimulation that produces broad electric fields, which presumably contribute to poor pitch and pitch-related performance by implant users. Bipolar or tripolar stimulation can generate focused electric fields but requires higher current to reach threshold and, more interestingly, has not produced any apparent improvement in cochlear implant performance. The present study addressed this dilemma by measuring psychophysical and physiological spatial selectivity with both broad and focused stimulations in the same cohort of subjects. Different current levels were adjusted by systematically measuring loudness growth for each stimulus, each stimulation mode, and in each subject. Both psychophysical and physiological measures showed that, although focused stimulation produced significantly sharper spatial tuning than monopolar stimulation, it could shift the tuning position or even split the tuning tips. The altered tuning with focused stimulation is interpreted as a result of poor electrode-to-neuron interface in the cochlea, and is suggested to be mainly responsible for the lack of consistent improvement in implant performance. A linear model could satisfactorily quantify the psychophysical and physiological data and derive the tuning width. Significant correlation was found between the individual physiological and psychophysical tuning widths, and the correlation was improved by log-linearly transforming the physiological data to predict the psychophysical data. Because the physiological measure took only one-tenth of the time of the psychophysical measure, the present model is of high clinical significance in terms of predicting and improving cochlear implant performance.
DOI: 10.1121/1.388872
发表时间: 1983-01-01
影响因子: 2.4
作者:
DESAUVAGE, RC;CAZALS, Y;ARAN, JM
通讯作者: ARAN, JM
DOI: 10.1016/j.heares.2010.08.006
发表时间: 2010-12-01
期刊: HEARING RESEARCH
影响因子: 2.8
作者:
Bierer, Julie Arenberg;Bierer, Steven M.;Middlebrooks, John C.
通讯作者: Middlebrooks, John C.
DOI: 10.1097/aud.0b013e3181bc7722
发表时间: 2010-02
期刊: Ear and hearing
影响因子: 3.7
作者:
Cullington HE;Zeng FG
通讯作者: Zeng FG
DOI: 10.1177/000348940211100505
发表时间: 2002-05-01
影响因子: 1.4
作者:
Dillier, N;Lai, WK;von Wallenberg, E
通讯作者: von Wallenberg, E
DOI: 10.1097/00003446-200004000-00009
发表时间: 2000-04-01
期刊: EAR AND HEARING
影响因子: 3.7
作者:
Brown, CJ;Hughes, ML;Gervais, J
通讯作者: Gervais, J