Characteristic Alterations of Network in Patients With Intraoperative Stimulation-Induced Seizures During Awake Craniotomy.
Characteristic Alterations of Network in Patients With Intraoperative Stimulation-Induced Seizures During Awake Craniotomy.
复制标题
DOI:
10.3389/fneur.2021.602716
复制
发表时间:
2021
影响因子:
3.4
通讯作者:
Jiang T
中科院分区:
文献类型:
--
作者:
Fang S;Zhou C;Wang L;Fan X;Wang Y;Zhang Z;Jiang T
Background: The use of electrocorticography (ECoG) to avoid intraoperative stimulation-induced seizure (ISS) during awake craniotomy is controversial. Although a standard direct cortical stimulating (DCS) protocol is used to identify the eloquent cortices and subcortical structures, ISS still occurs. Epilepsy is related to alterations in brain networks. In this study, we investigated specific alterations in brain networks in patients with ISS. Methods: Twenty-seven patients with glioma were enrolled and categorized into the ISS and non-ISS groups based on their history of ISS occurrence. A standard DCS protocol was used during awake craniotomy without ECoG supervision. Graph theoretical measurement was used to analyze resting-state functional magnetic resonance imaging data to quantitatively reveal alterations in the functional networks. Results: In the sensorimotor networks, the glioma significantly decreased the functional connectivity (FC) of four edges in the ISS group, which were conversely increased in the non-ISS group after multiple corrections (p < 0.001, threshold of p-value = 0.002). Regarding the topological properties, the sensorimotor network of all participants was classified as a small-world network. Glioma significantly increased global efficiency, nodal efficiency, and the sigma value, as well as decreased the shortest path length in the ISS group compared with the non-ISS group (p < 0.05). Conclusions: The specific alterations indicating patient susceptibility to ISS during DCS increased global and nodal efficiencies and decreased the shortest path length and FC induced by gliomas. If the patient has these specific alterations, ECoG is recommended to monitor after-discharge current during DCS to avoid ISS.
登录
查看更多内容
DOI:
10.1093/cercor/bhw157
发表时间:
2016-08
期刊:
Cerebral cortex (New York, N.Y. : 1991)
影响因子:
--
作者:
Fan L;Li H;Zhuo J;Zhang Y;Wang J;Chen L;Yang Z;Chu C;Xie S;Laird AR;Fox PT;Eickhoff SB;Yu C;Jiang T
通讯作者:
Jiang T
影响因子:
3.5
作者:
Fang, S.;Liang, J.;Jiang, T.
通讯作者:
Jiang, T.
影响因子:
4.1
作者:
Hervey-Jumper, Shawn L.;Li, Jing;Berger, Mitchel S.
通讯作者:
Berger, Mitchel S.
影响因子:
4.1
作者:
Sartorius, CJ;Berger, MS
通讯作者:
Berger, MS
DOI:
10.1007/bf03009510
发表时间:
1993-05-01
期刊:
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE
影响因子:
--
作者:
GIGNAC, E;MANNINEN, PH;GELB, AW
通讯作者:
GELB, AW