Impact of different coils on biochemical T2 and T2* relaxation time mapping of articular patella cartilage

Impact of different coils on biochemical T2 and T2* relaxation time mapping of articular patella cartilage
复制标题

不同线圈对髌骨软骨生化T2和T2*弛豫时间图的影响

DOI:
10.1007/s00256-013-1699-z
复制
发表时间:
2013
期刊:
影响因子:
2.1
通讯作者:
Welsch GH
Welsch GH
中科院分区:
医学4区
文献类型:
--
作者:
Pachowsky ML;Trattnig S;Apprich S;Mauerer A;Zbyn S;Welsch GH

文献摘要

参考文献

被引文献

相似文献

我们的研究的目的是评估T2和T2* 弛豫时间值在健康志愿者使用三种不同的线圈在3.0特斯拉MRI和他们的影响的定量values.Methods15志愿者进行了检查,在同一个3特斯拉MR单位使用三种不同的线圈:(i)专用的八通道膝关节相控阵线圈;(ii)八通道多用途线圈,和(iii)单通道1H表面线圈。T2和T2* 弛豫时间测量分别由多回波自旋回波制备 梯度回波序列对髌骨软骨进行半自动感兴趣区域分析。为了分层,进行了次区域分析(深-浅软骨层)。统计方差分析performed.ResultsThe平均定量T2值显示在所有比较组合的统计学显着差异。平均定量T2* 值之间的差异略低于T2评价,只有(i)和(ii)之间的比较显示出显著差异。T2和T2* 值的结果显示,与所使用的线圈无关,与深部区域相比,浅表区域中的值更高(p< 0.05)。观察信号变化,所有线圈在深层中显示出明显更高的值(因此更多的信号变化作为噪声的标志)。的可靠性的验证表明,一个高的类内相关系数,因此一个非常高的可扩展性(ICC为0.870和0.905之间的T2映射和0.879和0.888之间的T2 * mapping)。
ObjectiveThe purpose of our study was to assess T2 and T2* relaxation time values of patella cartilage in healthy volunteers using three different coils at 3.0 Tesla MRI and their influence on the quantitative values.MethodsFifteen volunteers were examined on the same 3-Tesla MR unit using three different coils: (i) a dedicated eight-channel knee phased-array coil; (ii) an eight-channel multi-purpose coil, and (iii) a one-channel 1H surface coil. T2 and T2* relaxation time measurements were prepared by a multi-echo spinecho respectively a gradient-echo sequence. A semi-automatic region-of-interest analysis was performed for patella cartilage. To allow stratification, a subregional analysis was carried out (deep-superficial cartilage layer). Statistical analysis-of-variance was performed.ResultsThe mean quantitative T2 values showed statistically significant differences in all comparison combinations. The differences between the mean quantitative T2* values were slightly less pronounced than the T2 evaluation and only the comparison between (i) and (ii) showed a significant difference. The results of T2 and T2* values showed, independent of the used coil, higher values in the superficial zone compared to the deep zone (p< 0.05). Looking at the signal alterations, all coils showed clearly higher values (and thus more signal alterations as a sign of noise) in the deep layer. The validation of the reliability showed a high intra-class correlation coefficient and hence a very high plausibility (ICC was between 0.870 and 0.905 for T2 mapping and between 0.879 and 0.888 for T2* mapping).ConclusionsThe present results demonstrate that biochemical T2 and T2* mapping is significantly dependent on the utilized coil.
DOI: 10.1097/00003086-200110001-00034
发表时间: 2001-10-01
影响因子: 4.2
作者:
Chung, CB;Frank, LR;Resnick, D
通讯作者: Resnick, D
DOI: 10.1002/jmri.20969
发表时间: 2007-08-01
影响因子: 4.4
作者:
Dietrich, Olaf;Raya, Jose G.;Schoenberg, Stefan O.
通讯作者: Schoenberg, Stefan O.
DOI: 10.1002/art.20000
发表时间: 2004-02-01
影响因子: --
作者:
Raynauld, JP;Martel-Pelletier, J;Pelletier, JP
通讯作者: Pelletier, JP
通过质子磁共振显微镜研究工程软骨组织对生化制剂的反应。
DOI: 10.1002/1529-0131(200007)43:7
发表时间: 2000
影响因子: --
作者:
Potter,K;Butler,JJ;Horton,WE;Spencer,RG
通讯作者: Spencer,RG